Particle identification using the (DELTA)E-E technique and pulse shape discrimination with the silicon detectors of the FAZIA project - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment Année : 2012

Particle identification using the (DELTA)E-E technique and pulse shape discrimination with the silicon detectors of the FAZIA project

S. Carboni
  • Fonction : Auteur
S. Barlini
  • Fonction : Auteur
L. Bardelli
  • Fonction : Auteur
M. Bini
  • Fonction : Auteur
G. Casini
  • Fonction : Auteur
A. Olmi
  • Fonction : Auteur
G. Pasquali
  • Fonction : Auteur
G. Poggi
  • Fonction : Auteur
A.A. Stefanini
  • Fonction : Auteur
G. Baiocco
  • Fonction : Auteur
R. Berjillos
  • Fonction : Auteur
Eric Bonnet
M. Bruno
  • Fonction : Auteur
I. Cruceru
  • Fonction : Auteur
M. Degerlier
  • Fonction : Auteur
J.A. Dueñas
  • Fonction : Auteur
F. Gramegna
  • Fonction : Auteur
A. Kordyasz
  • Fonction : Auteur
T. Kozik
  • Fonction : Auteur
V.L. Kravchuk
  • Fonction : Auteur
O. Lopez
T. Marchi
  • Fonction : Auteur
I. Martel
  • Fonction : Auteur
L. Morelli
  • Fonction : Auteur
H. Petrascu
  • Fonction : Auteur
E. Rosato
  • Fonction : Auteur
E. Vient
M. Vigilante
  • Fonction : Auteur
R. Alba
  • Fonction : Auteur
D. Santonocito
  • Fonction : Auteur
C. Maiolino
  • Fonction : Auteur

Résumé

The response of silicon-silicon-CsI(Tl) and silicon-CsI(Tl) telescopes to fragments produced in nuclear interactions has been studied. The telescopes were developed within the FAZIA collaboration. The capabilities of two methods are compared: (a) the standard ΔE-E technique and (b) the digital Pulse Shape Analysis technique (for identification of nuclear fragments stopped in a single Si-layer). In a test setup, nuclear fragments covering a large range in nuclear charge, mass and energy were detected. They were produced in nuclear reactions induced by a 35A MeV beam of 129Xe impinging on various targets. It was found that the ΔE-E correlations allow the identification of all isotopes up to Z∼25. With the digital Pulse Shape Analysis it is possible to fully distinguish the charge of stopped nuclei up to the maximum available Z (slightly over that of the beam, Z=54).

Dates et versions

in2p3-00656422 , version 1 (04-01-2012)

Identifiants

Citer

S. Carboni, S. Barlini, L. Bardelli, N. Le Neindre, M. Bini, et al.. Particle identification using the (DELTA)E-E technique and pulse shape discrimination with the silicon detectors of the FAZIA project. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2012, 664, pp.251-263. ⟨10.1016/j.nima.2011.10.061⟩. ⟨in2p3-00656422⟩