From Accuracy to Reliability and Robustness in Cardiac Magnetic Resonance Image Segmentation: A Review - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Applied Sciences Année : 2022

From Accuracy to Reliability and Robustness in Cardiac Magnetic Resonance Image Segmentation: A Review

Francesco Galati
  • Fonction : Auteur
  • PersonId : 1110744
Sébastien Ourselin
  • Fonction : Auteur
  • PersonId : 1141663
Maria A. Zuluaga

Résumé

Since the rise of deep learning (DL) in the mid-2010s, cardiac magnetic resonance (CMR) image segmentation has achieved state-of-the-art performance. Despite achieving inter-observer variability in terms of different accuracy performance measures, visual inspections reveal errors in most segmentation results, indicating a lack of reliability and robustness of DL segmentation models, which can be critical if a model was to be deployed into clinical practice. In this work, we aim to bring attention to reliability and robustness, two unmet needs of cardiac image segmentation methods, which are hampering their translation into practice. To this end, we first study the performance accuracy evolution of CMR segmentation, illustrate the improvements brought by DL algorithms and highlight the symptoms of performance stagnation. Afterwards, we provide formal definitions of reliability and robustness. Based on the two definitions, we identify the factors that limit the reliability and robustness of state-of-the-art deep learning CMR segmentation techniques. Finally, we give an overview of the current set of works that focus on improving the reliability and robustness of CMR segmentation, and we categorize them into two families of methods: quality control methods and model improvement techniques. The first category corresponds to simpler strategies that only aim to flag situations where a model may be incurring poor reliability or robustness. The second one, instead, directly tackles the problem by bringing improvements into different aspects of the CMR segmentation model development process. We aim to bring the attention of more researchers towards these emerging trends regarding the development of reliable and robust CMR segmentation frameworks, which can guarantee the safe use of DL in clinical routines and studies
Fichier principal
Vignette du fichier
applsci-12-03936-v3.pdf (461.38 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-03647673 , version 1 (20-04-2022)

Licence

Paternité

Identifiants

Citer

Francesco Galati, Sébastien Ourselin, Maria A. Zuluaga. From Accuracy to Reliability and Robustness in Cardiac Magnetic Resonance Image Segmentation: A Review. Applied Sciences, 2022, 12 (8), pp.3936. ⟨10.3390/app12083936⟩. ⟨hal-03647673⟩
59 Consultations
63 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More