Low duty-cycle pulsed irradiation reduces magnetization transfer and increases the inhomogeneous magnetization transfer effect - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Journal of Magnetic Resonance Année : 2018

Low duty-cycle pulsed irradiation reduces magnetization transfer and increases the inhomogeneous magnetization transfer effect

Résumé

Intense off-resonant RF irradiation can lead to saturation of the macromolecular pool magnetization and enhance bound pool dipolar order responsible for the inhomogeneous magnetization transfer (ihMT) effect, but the intensity of RF power in human imaging studies is limited by safety constraints on RF heat- ing. High RF intensities can still be achieved if applied in short pulses with low duty-cycle. Here we inves- tigate the benefits of low duty-cycle irradiation for MT and ihMT studies with both theoretical and experimental methods. Solutions for pulsed irradiation of a two-pool model including dipolar order effects were implemented. Experiments were conducted at 3 T in the brain and through the calf of healthy human subjects. 2D echo planar images were acquired following a preparation of RF irradiation with a 2 s train of 5 ms pulses repeated from between 10 to 100 ms for duty-cycles (DCs) of 50% to 5%, and at varying offset frequencies, and time averaged RF powers. MT and ihMT data were measured in regions of interest within gray mat- ter, white matter and muscle, and fit to the model. RF irradiation effects on signal intensity were reduced at 5% relative to 50% DCs. This reduced RF effect was much larger for single than dual frequency irradiation. 5% DC irradiation reduced single and dual fre- quency MT ratios but increased ihMT ratios up to 3 fold in brain tissues. Muscle ihMT increased by an even larger factor, depending on the frequency and applied power. The model predicted these changes with duty-cycle. The model fit the data well and constrained model parameters. Low duty-cycle pulsed irradiation reduces MT effects and markedly increases dipolar order effects. This approach is an attractive method to enhance ihMT signal-to-noise ratio and demonstrates a measurable ihMT effect in muscle tissue at 3 T under acceptable specific absorption rates. The effects of duty-cycle changes demonstrated in a separate MT/ihMT preparation provide a route for new applications in magnetization-prepared MRI sequences.
Fichier non déposé

Dates et versions

Identifiants

Citer

G. Varma, O.M. Girard, S. Mchinda, V.H. Prevost, A.K. Grant, et al.. Low duty-cycle pulsed irradiation reduces magnetization transfer and increases the inhomogeneous magnetization transfer effect. Journal of Magnetic Resonance, 2018, 296, pp.60-71. ⟨10.1016/j.jmr.2018.08.004⟩. ⟨hal-02059549⟩
44 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More