Aeroacoustic source analysis in a corrugated flow pipe using low-frequency mitigation

Muriel Amielh 1 Fabien Anselmet 1 Y. Jiang 2 Ulf Kristiansen 2 Pierre-Olivier Mattei 3 Daniel Mazzoni 4 Cédric Pinhede 3
3 Sons
LMA - Laboratoire de Mécanique et d'Acoustique [Marseille]
4 Sons
LMA - Laboratoire de Mécanique et d'Acoustique [Marseille]
Abstract : Our study is focused on a phenomenon often encountered in flow carrying pipes, since flow instabilities caused by geometric features may generate acoustic signals and thereafter interact with these signals in such a way that powerful pure tones are produced. A modern example is found in the so-called "singing risers", or the gas pipes connecting gas production platforms to the transport network. But the flow generated resonance in a fully corrugated circular pipe may be silenced by the addition of relatively low frequency flow oscillations induced by an acoustic generator. Experiments reported here, aimed at investigating in more detail the coupling between the flow in the pipe, the acoustically generated flow oscillations and the emitted resulting noise, are performed in a specifically designed facility. A rectangular transparent channel using glass walls enables us to use optical techniques to describe in detail the flow field in the corrugation vicinity, in addition to more standard hot-wire anemometry and acoustic pressure measurements with microphones, with and without the acoustically generated low-frequency oscillations.
Liste complète des métadonnées

https://hal.archives-ouvertes.fr/hal-01057978
Contributeur : Fabien Anselmet <>
Soumis le : lundi 25 août 2014 - 17:29:46
Dernière modification le : lundi 30 mars 2015 - 15:17:59

Identifiants

Citation

Muriel Amielh, Fabien Anselmet, Y. Jiang, Ulf Kristiansen, Pierre-Olivier Mattei, et al.. Aeroacoustic source analysis in a corrugated flow pipe using low-frequency mitigation. Journal of Turbulence, Taylor & Francis, 2014, 15 (10), pp.650-676. <10.1080/14685248.2014.928412>. <hal-01057978>

Partager

Métriques

Consultations de la notice

170