Diagnostic accuracy of quantitative real-time PCR assay versus clinical and Gram stain identification of bacterial vaginosis - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue European Journal of Clinical Microbiology and Infectious Diseases Année : 2010

Diagnostic accuracy of quantitative real-time PCR assay versus clinical and Gram stain identification of bacterial vaginosis

Résumé

The purpose of this investigation was to determine the diagnostic accuracy of quantitative real-time polymerase chain reaction (PCR) assay in diagnosing bacterial vaginosis versus the standard methods, the Amsel criteria and the Nugent score. The Amsel criteria, the Nugent score, and results from the molecular tool were obtained independently from vaginal samples of 163 pregnant women who reported abnormal vaginal symptoms before 20 weeks gestation. To determine the performance of the molecular tool, we calculated the kappa value, sensitivity, specificity, and positive and negative predictive values. Either or both of the Amsel criteria (≥3 criteria) and the Nugent score (score ≥7) indicated that 25 women (15%) had bacterial vaginosis, and the remaining 138 women did not. DNA levels of or exceeded 10 copies/mL or 10 copies/mL, respectively, in 34 (21%) of the 163 samples. Complete agreement between both reference methods and high concentrations of and was found in 94.5% of women (154/163 samples, kappa value = 0.81, 95% confidence interval 0.70-0.81). The nine samples with discordant results were categorized as intermediate flora by the Nugent score. The molecular tool predicted bacterial vaginosis with a sensitivity of 100%, a specificity of 93%, a positive predictive value of 73%, and a negative predictive value of 100%. The quantitative real-time PCR assay shows excellent agreement with the results of both reference methods for the diagnosis of bacterial vaginosis.

Mots clés

Fichier principal
Vignette du fichier
PEER_stage2_10.1007%2Fs10096-010-1039-3.pdf (200.49 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00618801 , version 1 (03-09-2011)

Identifiants

Citer

J.-P. Menard, C. Mazouni, F. Fenollar, Didier Raoult, L. Boubli, et al.. Diagnostic accuracy of quantitative real-time PCR assay versus clinical and Gram stain identification of bacterial vaginosis. European Journal of Clinical Microbiology and Infectious Diseases, 2010, 29 (12), pp.1547-1552. ⟨10.1007/s10096-010-1039-3⟩. ⟨hal-00618801⟩
71 Consultations
438 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More