Impedance Measurement of Each Cell of a 10 W PEMFC Stack under Load - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Journal of The Electrochemical Society Année : 2004

Impedance Measurement of Each Cell of a 10 W PEMFC Stack under Load

Résumé

The impedance of each cell of a 10 W PEMFC stack under conditions of natural running is determined independently of the others. No electronic load is used during the experiments, even if the current flowing through the stack is greater than the current range of our electrochemical apparatus. Only a power resistor is needed, which is simpler and cheaper to use. It is shown that cell by cell, a gas starvation occurs in the stack when H2 and O2 circulate in cocurrent, the impedance increasing from the cell which is on the gas inlet-side to the cell which is on the gas outlet-side. It is also shown that the part of the internal resistance of a cell which is due to the polymer membrane is ~40%. The method proposed in this paper can be applied whatever the number of cells in the stack, and could be useful in order to detect a failure due to only one cell, whereas the others run well.

Domaines

Matériaux

Dates et versions

hal-00417921 , version 1 (17-09-2009)

Identifiants

Citer

Jean-Paul Diard, Nicolas Glandut, Bernard Le Gorrec, Claude Montella. Impedance Measurement of Each Cell of a 10 W PEMFC Stack under Load. Journal of The Electrochemical Society, 2004, 151 (12), pp. A2193-A2197. ⟨10.1149/1.1815152⟩. ⟨hal-00417921⟩