A novel method to correct repolarization time estimation from unipolar electrograms distorted by standard filtering - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Medical Image Analysis Année : 2021

A novel method to correct repolarization time estimation from unipolar electrograms distorted by standard filtering

Résumé

Reliable patient-specific ventricular repolarization times (RTs) can identify regions of functional block or afterdepolarizations, indicating arrhythmogenic cardiac tissue and the risk of sudden cardiac death. Unipolar electrograms (UEs) record electric potentials, and the Wyatt method has been shown to be accurate for estimating RT from a UE. High-pass filtering is an important step in processing UEs, however, it is known to distort the T-wave phase of the UE, which may compromise the accuracy of the Wyatt method. The aim of this study was to examine the effects of high-pass filtering, and improve RT estimates derived from filtered UEs. We first generated a comprehensive set of UEs, corresponding to early and late activation and repolarization, that were then high-pass filtered with settings that mimicked the CARTO filter. We trained a deep neural network (DNN) to output a probabilistic estimation of RT and a measure of confidence, using the filtered synthetic UEs and their true RTs. Unfiltered ex-vivo human UEs were also filtered and the trained DNN used to estimate RT. Even a modest 2 Hz high-pass filter imposes a significant error on RT estimation using the Wyatt method. The DNN outperformed the Wyatt method in 62.75% of cases, and produced a significantly lower absolute error (p=8.99E−13), with a median of 16.91 ms, on 102 ex-vivo UEs. We also applied the DNN to patient UEs from CARTO, from which an RT map was computed. In conclusion, DNNs trained on synthetic UEs improve the RT estimation from filtered UEs, which leads to more reliable repolarization maps that help to identify patient-specific repolarization abnormalities.
Fichier principal
Vignette du fichier
CRCTB_MIA_2021_Langfield.pdf (2.36 Mo) Télécharger le fichier
Origine Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-03811712 , version 1 (12-10-2022)

Licence

Identifiants

Citer

Peter Langfield, Yingjing Feng, Laura R. Bear, Josselin Duchateau, Rafael Sebastian, et al.. A novel method to correct repolarization time estimation from unipolar electrograms distorted by standard filtering. Medical Image Analysis, 2021, 72, ⟨10.1016/j.media.2021.102075⟩. ⟨hal-03811712⟩
2 Consultations
53 Téléchargements

Altmetric

Partager

Gmail Mastodon Facebook X LinkedIn More