ANALYSING FLUX DECLINE IN DEAD-END FILTRATION
Résumé
Can we rely on the analysis of flux decline to evaluate the risks of a filter media to be clogged during filtration of a given particle suspension? This important issue can be dealt with a macroscopic approach described in this paper. We seek to identify and quantify the successive prevailing mechanisms which occur during a filtration run, directly and solely from experimental flux data. This is achieved from the collection of experimental data (filtrate volume V versus time t) and the use of the differential equation . A methodology is then proposed to define and validate experimental procedures with the purpose of quantifying occurring fouling mechanism. For the purpose of illustrating its valuable impact for a bench marking procedure, the methodology has been applied on a model system composed of a bentonite suspension and a series of microfiltration membranes of different structures.
Domaines
Génie des procédés
Fichier principal
Grenier2.pdf (373.08 Ko)
Télécharger le fichier
Figures_Article_Alexia_correction-2_AG_-1.ppt (788.5 Ko)
Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)