Proteomics. 2006 April; 6(8): 2350–4.
doi: 10.1002/pmic.200500567.

Sequence coverage in mass spectrometry analysis of protein digestion-derived peptides is a key issue for detailed characterization of proteins or identification at low quantities. In gel-based proteomics studies, the sequence coverage greatly depends on the protein detection method. It is shown here that ammoniacal silver detection methods offer improved sequence coverage over standard silver nitrate methods, while keeping the high sensitivity of silver staining With the development of 2D-PAGE-based proteomics, another burden is placed on the detection methods used for protein detection on 2D-gels. Besides the classical requirements of linearity, sensitivity and homogeneity from one protein to another, detection methods must now take into account another aspect, namely their compatibility with mass spectrometry. This compatibility is evidenced by two different and complementary aspects, which are i) the absence of adducts and artefactual modifications on the peptides obtained after protease digestion of a protein detected and digested in –gel and ii) the quantitative yield of peptides recovered after digestion and analyzed by the mass spectrometer. While this quantitative yield is not very important per se, it is however a crucial parameter as it strongly influences the signal to noise ratio of the mass spectrum, and thus the number of peptides that can be detected from a given protein input, especially at low protein amounts. This influences in turn the sequence coverage, and thus the detail of the analysis provided by the mass spectrometer.

MESH keywords: Ammonia, chemistry, Electrophoresis, Gel, Two-Dimensional, Humans, Isoelectric Focusing, Mass Spectrometry, methods, Peptides, chemistry, Proteomics, instrumentation, methods, Reproducibility of Results, Silver Staining, methods

Author keywords: electrophoresis, silver staining, mass spectrometry

Several detection methods are widely used for protein visualization after 2D gel electrophoresis. The most popular one is probably colloidal Coomassie blue staining [1]. Although this method is not very sensitive, it affords a very good compatibility with mass spectrometry. It also has gained popularity in the early days of proteomics, when its sensitivity matched almost exactly the needs in protein amounts required for a decent analysis by mass spectrometry. With the improvement of the mass spectrometers, associated robotics etc…, this is no longer the case, and detection by colloidal Commassie either requires useless consumption of sample or leads to low numbers of analyzable proteins due to undetection. Fluorescent detection methods offer an interesting alternative, and metal chelate-based methods [2, 3] have become increasingly popular. In their most recent versions [4], these methods offer an interesting sensitivity allied to a very good compatibility with mass spectrometry analysis (see for example [3]). These methods are however not easy to use in small proteomics laboratories. Besides the expensive laser scanners or CCD cameras required for quantitative analysis, spot excision must be performed under UV light, which induces in turn collateral problems such as safety problems and photobleaching problems, both increasing when large number of spots are to be excised in comprehensive proteomics studies.

Last but not least, silver staining still offers the maximal sensitivity, and all the ancillary advantages associated on light absorption-based methods, such as easy visualization and quantitation (although the linear dynamic range of silver staining is not very good), and easy spot excision. However, silver staining is plagued by a rather poor compatibility with mass spectrometry. This has been exemplified in numerous papers (e.g. in [5] and [6]) and is only partially alleviated by destaining procedures [7] after silver staining and prior to protein digestion. The interference between silver staining and mass spectrometry has been investigated in detail [8], and this has evidenced the crucial role of the formaldehyde used in all silver staining methods as the silver-reducing agent. This puts forward an interference mechanism in which protein crosslinking by formaldehyde in alkaline media could be the major phenomenon taking place. If this mechanism is true, ammoniacal silver methods [9] should provide an increased compatibility with mass spectrometry, as the development step takes place in an acidic medium and is made in the presence of the excess ammonia carried over with silver in the silvering agent, this ammonia acting as a scavenger for formaldehyde.

We therefore tested silver nitrate, glutaraldehyde-free silver ammonia and RuBPS as detection methods after 2D PAGE. As shown on figure 1, both silver nitrate and silver ammonia give similar detection thresholds (see also [9]) which were better than those obtained with RuBPS. We then selected proteins of various abundances, hydrophobicities, Mw and pI for mass spectrometry analysis, which was carried out by Peptide Mass Fingerprinting with a MALDI instrument according to classical methods [3]. For silver-stained gels, with silver nitrate or silver ammonia, the excised spots were destained by ferricyanide-thiosulfate [7] as soon as possible after silver staining, as this was shown to improve the mass spectrometry results [8]. The results are summarized on table 2. They clearly show that protein behaviours are variable but show however a clear trend that can be summarized as follows. Silver-stained spots give signals that are at best equal to those obtained with RuBPS (e.g. Band 3) but that can also be inferior. In the latter case, silver-ammonia and the Shevchenko methods gives results that are superior or equal to those obtained with silver nitrate (e.g. PGM, Ran, endoplasmin, hsp90). In trying to go further and understand why some peptides are missing in silver-stained gels compared to RuBPS-stained gels, we could not find obvious trends (e.g. selective loss of lysine-containing peptides compared to arginine-containing peptides, influence of content in nucleophilic amino acids such as Ser, Cys, Thr or Tyr etc…) so that the exact mechanism of peptide losses is still unknown.

On a more practical basis, it can be concluded that silver ammonia is an interesting choice over silver nitrate as a compromise between sensitivity, linearity, absence of background, ease of use, cost (including hardware) and mass spectrometry compatibility. However, it must be kept in mind that ammoniacal silver is not compatible with all electrophoresis systems. Although it is fully compatible with the popular Tris-glycine system and the more recent Tris taurine system [13], it is not compatible with the Tris-tricine systems [14, 15]. It can also be rendered compatible with supported gels [16], but in all cases optimal performance is obtained when thiosulfate is included in the gel upon polymerization [17], which precludes the use of ready-made gels. However, in this latter case, substantial background reduction can be obtained by a short rinse in a dilute solution of thiosulfate just before development [18]. Last but not least, optimal performance strongly depends on the silver-ammonia ratio [19], which controls both the sensitivity and the tendency to background staining. This parameter is to be considered as critical in long-term experiments, due to the short shelf-life of ammonia solutions. A good procedure for controlling this parameter is to use ready-to-use, titrated ammonium hydroxide solutions.

When these conditions are met, ammoniacal silver is clearly the best silver-based detection methods for proteomics studies. While the sequence coverage is often inferior to the ones obtained with the Shevchenko methods, the background due to carrier ampholytes [20] and chromatic effects encountered with the latter method preclude its use as a quantitative method. This strongly decreases the interest of the method, as one of the main interests of the silver-ammonia method is the ability to use the same experiment for the quantitative image analysis and mass spectrometry analysis of spots at a much inferior cost than fluorescent staining.