TESTING OF THE THERMOMARKER : IMPORTANCE OF HYSTERESIS - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Journal de Physique IV Proceedings Année : 1991

TESTING OF THE THERMOMARKER : IMPORTANCE OF HYSTERESIS

M. Raymond
  • Fonction : Auteur
E. Weynant
  • Fonction : Auteur

Résumé

After a short presentation of the industrial machines used by the process of treatment of shape memory alloys, the paper will explain the special feature of the Thermomarker which falls in with two tests of working : one during the martensite-austenite transformation, one during the austenite-martensite transformation. So that the good work of the Thermomarker is bound directly to hysteresis. The authors will display not only results but also the analysis they have made to get a goodcorrelation between this working hysteresis and the hysteresis of the martensitic transformation in shape memory alloy.

Domaines

Articles anciens
Fichier principal
Vignette du fichier
ajp-jp4199101C426.pdf (1.03 Mo) Télécharger le fichier
Origine : Accord explicite pour ce dépôt

Dates et versions

jpa-00250574 , version 1 (04-02-2008)

Identifiants

Citer

M. Raymond, E. Weynant. TESTING OF THE THERMOMARKER : IMPORTANCE OF HYSTERESIS. Journal de Physique IV Proceedings, 1991, 01 (C4), pp.C4-169-C4-174. ⟨10.1051/jp4:1991426⟩. ⟨jpa-00250574⟩