Simple improved control of phase error compensation for low power operation of PV grid-connected inverter with LCL filter - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue European Journal of Electrical Engineering Année : 2014

Simple improved control of phase error compensation for low power operation of PV grid-connected inverter with LCL filter

Baochao C. Wang
  • Fonction : Auteur
Manuela Sechilariu
Fabrice Locment
  • Fonction : Auteur
  • PersonId : 863716

Résumé

Obvious grid power factor degradation can often be observed when using LCL filter for grid-connected photovoltaic systems. This paper analyzes degradation causes and a phase error compensation structure is proposed. Experimental results conclude that the proposed compensation structure improves the grid power quality in case of low PV production, in both power factor and harmonics.
Fichier non déposé

Dates et versions

hal-01955023 , version 1 (14-12-2018)

Identifiants

Citer

Baochao C. Wang, Manuela Sechilariu, Fabrice Locment. Simple improved control of phase error compensation for low power operation of PV grid-connected inverter with LCL filter. European Journal of Electrical Engineering, 2014, 17 (1-2), pp.27-45. ⟨10.3166/EJEE.17.27-45⟩. ⟨hal-01955023⟩