Complementarity of a Photon-Counting system and Radioscopy for Inspection of Cast Aluminium Components - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue NDT & E International Année : 2005

Complementarity of a Photon-Counting system and Radioscopy for Inspection of Cast Aluminium Components

Résumé

This study aims at establishing x-ray methods for inspection of cast aluminium components by combining two approaches, a radioscopic inspection, and a photon counting system. Indeed, radioscopy is widely used in castings inspection for automatic defect detection and is an efficient method for characterising rather small thicknesses, typically less than 40 mm. However cast components often show a high range of thicknesses and imaging the whole range is difficult. We propose to use photon-counting measurements to complement the radioscopic image for high thicknesses. Photon counting is not an imaging tool, but the thickness sensitivity obtained from photon-counting measurements (number of x-ray photons transmitted through the object) is much better than what can be obtained by classical radioscopy for up to 60 mm of aluminium. For high thicknesses of aluminium, within small volumes where defects are believed to be critical, the photon-counting system allows getting information additional to that obtained from classical radioscopy images.
Fichier non déposé

Dates et versions

hal-01017478 , version 1 (02-07-2014)

Identifiants

  • HAL Id : hal-01017478 , version 1

Citer

Emmanuelle Cendre, Valerie Kaftandjian, Gwenaele Lecomte, Kristian Kjaer. Complementarity of a Photon-Counting system and Radioscopy for Inspection of Cast Aluminium Components. NDT & E International, 2005, 38, pp.239-250. ⟨hal-01017478⟩
30 Consultations
0 Téléchargements

Partager

Gmail Facebook X LinkedIn More