Communication Dans Un Congrès Année : 2011

2DH modelling of a reservoir flushing compared with LSPIV measurements

B. Camenen
André Paquier
J. Le Coz
  • Fonction : Auteur
Guillaume Dramais
M. de Linares
  • Fonction : Auteur

Résumé

A reservoir flushing was completed on September 2008 in the Longefan reservoir (Arc en Maurienne River, France). This reservoir (approximately 300m×500m) is part of the EDF (French Electricity company) hydropower system. It is mainly used for the sedimentation of the water released from the upstream hydropower plant and for temporary storage for the next plant. LSPIV measurements were completed during the flushing event using three cameras covering the main zones of interest (entrance, main channel and exit). For each movie, biologically degradable chips were injected to produce visible patterns on the surface flow and facilitate the LSPIV processing. Two 2DH hy drodynamic models (Rubar20 and Telemac2D) were applied to the system and their results were compared to the experimental data. Advantages and limits of these models were discussed. In particular, the effects of water level and wind were studied as well as the direction of the jet entering the reservoir.
Fichier principal
Vignette du fichier
LY2011-PUB00032674.pdf (2.11 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00649984 , version 1 (09-12-2011)

Identifiants

Citer

B. Camenen, André Paquier, A. Bouarab, J. Le Coz, Guillaume Dramais, et al.. 2DH modelling of a reservoir flushing compared with LSPIV measurements. Congrès AIRH, Jun 2011, Brisbane, Australia. 8 p. ⟨hal-00649984⟩

Collections

IRSTEA INRAE
92 Consultations
98 Téléchargements

Partager

Gmail Facebook X LinkedIn More