Ficoll as testing material for diffusion weighted imaging-quality assurance phantoms - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Magnetic Resonance Imaging Année : 2021

Ficoll as testing material for diffusion weighted imaging-quality assurance phantoms

Andrea Barucci
  • Fonction : Auteur
Alessandra Flori
  • Fonction : Auteur
Roberto Carpi
  • Fonction : Auteur
Daniele De Marchi
  • Fonction : Auteur
Marco Esposito
  • Fonction : Auteur
Luca Menichetti
  • Fonction : Auteur
Roberto Pini
  • Fonction : Auteur
Fulvio Ratto
  • Fonction : Auteur
Giacomo Belli
  • Fonction : Auteur

Résumé

Purpose The aim of this work is to test the use of aqueous solutions of Ficoll®**, a highly branched polymer displaying crowding properties, to build a phantom suitable for Diffusion Weighted Imaging (DWI) in Magnetic Resonance Imaging (MRI). Methods We developed a test object made of a cylindrical plastic container with a precise geometrical arrangement suitable for measuring several samples at the same time. The container was designed to host single vials with variable geometry and number, and to fit inside common commercial head coils for MRI scanners. In our experiments, vials were filled with 8 aqueous solutions of Ficoll 70 and Ficoll 400 spanning a range of polymer concentration from 5 to 30% by weight. Vials containing ultra-pure water were also used as reference. Experiments were performed on both 1.5 and 3 T clinical scanners (GE, Philips and Siemens), under the conditions of a standard clinical examination. Results The geometry of the phantom provided reduced imaging artifacts, especially image distortions at magnetic interfaces. We found that the Apparent Diffusion Coefficient (ADC) varied in the range of 0.00125–0.00223 mm2/s and decreased with Ficoll concentration. ADC vs Ficoll concentration exhibited a linear trend. Results were consistent over time and among different MRI clinical scanners, showing an average variability of 3% at 1.5 T and of 7.5% at 3 T. Moreover, no substantial difference was found between Ficoll 70 and 400. By varying Ficoll concentration, ADC can be modulated to approach tissue-mimicking values. Preliminary results for relaxation measurements proved that both T1 and T2 decreased with Ficoll concentration in the ranges 1.3–2.4 s and 150–800 ms respectively. Conclusions In this work, we propose a 3D phantom design based on the widespread crowding agent Ficoll, which is suitable for DWI quality assurance purposes in MRI acquisitions. Aqueous Ficoll solutions provide good performance in terms of stability, ease of preparation, and safety.
Fichier non déposé

Dates et versions

hal-03000944 , version 1 (12-11-2020)

Identifiants

Citer

Andrea Barucci, Alessandra Flori, Roberto Carpi, Daniele De Marchi, Marco Esposito, et al.. Ficoll as testing material for diffusion weighted imaging-quality assurance phantoms. Magnetic Resonance Imaging, 2021, 76, pp.1-7. ⟨10.1016/j.mri.2020.11.001⟩. ⟨hal-03000944⟩
63 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More