Assessment of Copy Number Variation using the Illumina Infinium 1M SNP-array: A comparison of methodological approaches in the Spanish Bladder Cancer / EPICURO Study. - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Human Mutation Année : 2011

Assessment of Copy Number Variation using the Illumina Infinium 1M SNP-array: A comparison of methodological approaches in the Spanish Bladder Cancer / EPICURO Study.

Gaëlle Marenne
Nathaniel Rothman
  • Fonction : Auteur
  • PersonId : 906255
Daniel Rico
  • Fonction : Auteur
  • PersonId : 906256
Guillermo Pita
  • Fonction : Auteur
  • PersonId : 899479
David G Pisano
  • Fonction : Auteur
  • PersonId : 906257
Debra T Silverman
  • Fonction : Auteur
  • PersonId : 906259
Alfonso Valencia
  • Fonction : Auteur
  • PersonId : 906260
Francisco X Real
  • Fonction : Auteur
  • PersonId : 870260
Stephen J Chanock
  • Fonction : Auteur
  • PersonId : 886362

Résumé

High-throughput SNP-array technologies allow to investigate CNVs in genome-wide scans and specific calling algorithms have been developed to determine CNV location and copy number. We report the results of a reliability analysis comparing data from 96 pairs of samples processed with CNVpartition, PennCNV and QuantiSNP for Infinium Illumina Human 1Million probe chip data. We also performed a validity assessment with multiplex ligation-dependent probe amplification (MLPA) as a reference standard. The number of CNVs per individual varied according to the calling algorithm. Higher numbers of CNVs were detected in saliva than in blood DNA samples regardless of the algorithm used. All algorithms presented low agreement with mean Kappa Index (KI) <66. PennCNV was the most reliable algorithm (KIw=98.96) when assessing the number of copies. The agreement observed in detecting CNV was higher in blood than in saliva samples. When comparing to MLPA, all algorithms identified poorly known copy aberrations (sensitivity=0.19-0.28). In contrast, specificity was very high (0.97-0.99). Once a CNV was detected, the number of copies was truly assessed (sensitivity>0.62). Our results indicate that the current calling algorithms should be improved for high performance CNV analysis in genome-wide scans. Further refinement is required to assess CNVs as risk factors in complex diseases.

Mots clés

Fichier principal
Vignette du fichier
PEER_stage2_10.1002%2Fhumu.21398.pdf (1.68 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00610793 , version 1 (25-07-2011)

Identifiants

Citer

Gaëlle Marenne, Benjamín Rodríguez Santiago, Montserrat García-Closas, Luis Alberto Pérez Jurado, Nathaniel Rothman, et al.. Assessment of Copy Number Variation using the Illumina Infinium 1M SNP-array: A comparison of methodological approaches in the Spanish Bladder Cancer / EPICURO Study.. Human Mutation, 2011, 32 (2), pp.240. ⟨10.1002/humu.21398⟩. ⟨hal-00610793⟩

Collections

UNIV-PARIS7 PEER
158 Consultations
88 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More