A Reliability Test on PBGA Packaging Through Piezoresistive Stress Sensor - Archive ouverte HAL Accéder directement au contenu
Ouvrages Année : 2009

A Reliability Test on PBGA Packaging Through Piezoresistive Stress Sensor

Résumé

Plastic packaging is the mainstream on microelectronic packaging technology at present. As the continuous requirements for smaller but higher density products, failure and reliability issues on MEMS/MOEMS packaging because of the hygroscopic swelling mismatch stress become more and more serious. To this end, this paper presented the stress monitoring methodologies as well as the reliability tests on a typical PBGA (Plastic Ball-Grid-Array) packaging due to hygroscopic effects through the measurements with the piezoresistive stress sensors. It is concluded from the experiments in this work that the hygroscopic mismatch stress is significant for the packaging, and the Weibull reliability model is suitable for the PBGA packaging. In addition, piezoresistive sensors were proven useful for monitoring the stress on the chip inside the packaging structure.
Fichier principal
Vignette du fichier
cr1013.pdf (265.51 Ko) Télécharger le fichier
Origine : Accord explicite pour ce dépôt
Loading...

Dates et versions

hal-00400577 , version 1 (01-07-2009)

Identifiants

  • HAL Id : hal-00400577 , version 1

Citer

C.-H. Liu, H. Chung, D.-W. Yang, K.-F. Tseng, B.-J. Lwo. A Reliability Test on PBGA Packaging Through Piezoresistive Stress Sensor. EDA Publishing, pp.4, 2009. ⟨hal-00400577⟩
22 Consultations
94 Téléchargements

Partager

Gmail Facebook X LinkedIn More