Inertial measurement unit compared to an optical motion capturing system in post-stroke individuals with foot-drop syndrome

Résumé

BackgroundFunctional electrical stimulation (FES) can be used for compensation of foot-drop for post-stroke individuals by pre-programmed fixed stimulation; however, this stimulation seems no more effective than mechanical ankle foot orthoses.ObjectiveWe evaluated the metrological quality of inertial sensors for movement reconstruction as compared with the gold-standard motion capturing system, to couple FES with inertial sensors to improve dorsiflexion on the paretic side, by using an adaptive stimulation taking into account individuals’ performance post-stroke.MethodsAdults with ischemic or hemorrhagic stroke presenting foot-drop and able to walk 10 m, were included from May 2016 to June 2017. Those with passive ankle dorsiflexion < 0° with the knee stretched were excluded. Synchronous gait was analyzed with the VICON© system as the gold standard and inertial measurement units (IMUs) worn by participants. The main outcome was the dorsiflexion angle at the heel strike and mid-swing phase obtained from IMUs and the VICON system. Secondary outcomes were: stride length, walking speed, maximal ankle dorsiflexion velocity and fatigue detection.ResultsWe included 26 participants [18 males; mean age 58 (range 45–84) years]. During heel strike, the dorsiflexion angle measurements demonstrated a root mean square error (RMSE) of 5.5°; a mean average error (MAE) of 3.9°; Bland-Altman bias of − 0.1° with limits of agreement − 10.9° to + 10.7° and good intra-class correlation coefficient (ICC) at 0.87 between the 2 techniques. During the mid-swing phase, the RMSE was 5.6; MAE 3.7°; Bland-Altman bias − 0.9° with limits of agreement − 11.7° to + 9.8° and ICC 0.88. Good agreement was demonstrated for secondary outcomes and fatigue detection.
Fichier principal
Vignette du fichier
S1877065719300570.pdf (547.57 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

lirmm-02121637 , version 1 (22-08-2022)

Licence

Paternité - Pas d'utilisation commerciale

Identifiants

Citer

François Feuvrier, Benoît Sijobert, Jérome Froger, Christine Azevedo Coste, Karolina M. Griffiths, et al.. Inertial measurement unit compared to an optical motion capturing system in post-stroke individuals with foot-drop syndrome. Annals of Physical and Rehabilitation Medicine, 2020, 63 (3), pp.195-201. ⟨10.1016/j.rehab.2019.03.007⟩. ⟨lirmm-02121637⟩
127 Consultations
85 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More