H. W. Strauss, ªA Scintiphotographic Method for Measuring Left Ventricular Ejection Fraction in Man Without Cardiac Catheterization,º Am, J. Cardiology, vol.28, pp.985-991, 1971.

J. Sklansky and D. Ballard, ªTumor Detection in Radiographs, Computers and Biomedical Research, vol.6, issue.4, pp.299-321, 1973.

S. Pizer and A. E. Todd-pokropek, Improvement of scintigrams by computer processing, Seminars in Nuclear Medicine, vol.8, issue.2, pp.125-146, 1978.
DOI : 10.1016/S0001-2998(78)80036-1

º. Proc, Information Processing on Medical Imaging, pp.1-508, 1999.

T. Mcinerney and D. Terzopolous, Deformable models in medical image analysis: a survey, Medical Image Analysis, vol.1, issue.2, pp.91-108, 1996.
DOI : 10.1016/S1361-8415(96)80007-7

J. B. Maintz and M. A. , A survey of medical image registration, Medical Image Analysis, vol.2, issue.1, pp.1-16, 1998.
DOI : 10.1016/S1361-8415(01)80026-8

R. Shahidi, R. Tombropoulos, and R. P. Grzeszczuk, ªClinical Applications of Three-Dimensional Rendering of Medical Data Sets, Proc. IEEE, pp.555-568, 1998.

S. Lavallee, ªRegistration for Computer Integrated Surgery: Methodology and State of the Art,º Computer Integrated Surgery, pp.77-97, 1996.

M. Yachida, M. Ykeda, and S. Tsuji, ªA Plan-Guided Analysis of Cineangiograms for Measurement of Dynamic Behavior of the Heart Wall, IEEE Trans. Pattern Analysis and Machine Intelligence, vol.2, pp.537-543, 1980.

A. Martelli, An application of heuristic search methods to edge and contour detection, Communications of the ACM, vol.19, issue.2, pp.73-83, 1976.
DOI : 10.1145/359997.360004

M. Yanagisawa, ªRegistration of Locally Distorted Images by Multiwindow Pattern Matching and Displacement Interpolation: The Proposal of an Algorithm and Its Application to Digital Subtraction Angiography, Proc. Seventh Int'l Conf. Pattern Recognition, M. Levine, pp.288-1291, 1984.

M. Fitzpatrick, J. Greffenstette, D. Pickens, M. Mazer, and J. Perry, ªA System for Image Registration in Digital Subtraction Angiography ,º Information Processing in Medical Imaging, pp.415-434, 1987.

E. Meijering, W. Niessen, and M. Viergever, Retrospective motion correction in digital subtraction angiography: a review, IEEE Transactions on Medical Imaging, vol.18, issue.1, pp.2-21, 1999.
DOI : 10.1109/42.750248

A. Klein, F. Lee, and A. Amini, Quantitative coronary angiography with deformable spline models, IEEE Transactions on Medical Imaging, vol.16, issue.5, pp.468-482, 1997.
DOI : 10.1109/42.640737

H. Gelberg, B. Brundage, S. Glantz, and W. Parmley, Quantitative left ventricular wall motion analysis: a comparison of area, chord and radial methods, Circulation, vol.59, issue.5, pp.991-1000, 1979.
DOI : 10.1161/01.CIR.59.5.991

M. Fujita, S. Sasayama, C. Kawai, S. Eiho, and M. Kuwahara, ªAutomatic Processing of Cineventriculograms for Analysis of Regional Myocardial Function, Circulation, vol.63, issue.5 1, pp.65-1074, 1981.

C. E. Metz, ªEvaluation of Image Quality by ROC Analysis: Concepts, Techniques, and Future Possibilities, Japanese J. Radiological Technology, vol.4, pp.990-1002, 1985.

H. Barrett and C. Abbey, ªBayesian Detection of Random Signals on Random Backgrounds, Proc. Information Processing in Medical Imaging, pp.155-166, 1997.

R. Schudy and D. Ballard, ªModel-Detection of Cardiac Chambers in Ultrasound Images, 1978.

R. Bajcsy, R. Lieberson, and M. Reivich, A Computerized System for the Elastic Matching of Deformed Radiographic Images to Idealized Atlas Images, Journal of Computer Assisted Tomography, vol.7, issue.4, pp.618-625, 1983.
DOI : 10.1097/00004728-198308000-00008

H. P. Chan, K. Doi, S. Galhotra, C. J. Vyborny, H. Macmahon et al., Image feature analysis and computer-aided diagnosis in digital radiography. I. Automated detection of microcalcifications in mammography, Medical Physics, vol.14, issue.4, pp.538-548, 1987.
DOI : 10.1118/1.596065

F. Shtern, M. Vannier, and D. Winfield, ªReport of the Working Group on Digital Mammography: Computer Aided Diagnosis and 3D Image Analysis and Display,º Technical Report, U.S. Public Health Services's Office on Women's Health and the Nat'l Cancer Inst, 1998.

H. Niemann, H. Bunke, I. Hofmann, G. Sagerer, F. Wolf et al., ªA Knowledge Based System for Analysis of Gated Blood Pool Studies, IEEE Trans. Pattern Analysis and Machine Intelligence, vol.7, issue.3, pp.246-259, 1985.

J. S. Duncan, Knowledge Directed Left Ventricular Boundary Detection in Equilibrium Radionuclide Angiocardiography, IEEE Transactions on Medical Imaging, vol.6, issue.4, pp.325-336, 1987.
DOI : 10.1109/TMI.1987.4307851

C. Han, K. Lin, W. Wee, R. Mintz, and D. Purembka, ªKnowledge- Based Image Analysis for Automated Boundary Extraction of Transesophageal Echocardiographic Left Ventricular Images, IEEE Trans. Medical Imaging, vol.4, pp.602-610, 1991.

M. Kass, A. Witkin, and D. Terzopoulus, ªSnakes: Active Contour Models,º Int, J. Computer Vision, vol.1, pp.312-331, 1988.
DOI : 10.1007/bf00133570

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.124.5318

M. O. Donnell, J. Gore, and W. , Toward an automated analysis system for nuclear magnetic resonance imaging. II. Initial segmentation algorithm, Medical Physics, vol.13, issue.3, pp.293-297, 1986.
DOI : 10.1118/1.595916

D. Ortendahl and J. Carlson, ªSegmentation of Magnetic Resonance Images Using Fuzzy Clustering, Proc. Information Processing in Medical Imaging, pp.91-106, 1987.

J. Koenderinck, The structure of images, Biological Cybernetics, vol.27, issue.269, pp.363-370, 1984.
DOI : 10.1007/BF00336961

J. Gauch, W. Oliver, and S. Pizer, ªMultiresolution Shape Descriptions and Their Applications in Medical Imaging, Proc. Information Processing in Medical Imaging, pp.131-180, 1987.

C. De-graaf, K. Vincken, M. Viergever, J. Koenderinck, F. Appelman et al., Ying Lie, ªA Hyperstack for the Segmentation of 3D Images, Proc. Information Processing in Medical Imaging, pp.399-413, 1989.

D. Fritsch, S. Pizer, L. Yu, V. Johnson, and E. Chaney, ªSegmentation of Medical Image Objects Using Deformable Shape Loci, Proc. Information Processing in Medical Imaging, pp.127-140, 1997.

D. Morris, ªAn Evaluation of the Use of Texture Measures for Tissue Characterization of Ultraound Images of in Vivo Human Placenta, Medicine and Biology, vol.14, issue.1, pp.387-395, 1988.

J. Meunier, M. Bertrand, and G. Mailloux, ªA Model for Dynamic Texture Analysis in Two-Dimensional Echocardiograms of the Myocardium, Proc. SPIE Pattern Recognition Acoustical Image, pp.193-200, 1987.

J. Meunier and M. Bertrand, Ultrasonic texture motion analysis: theory and simulation, IEEE Transactions on Medical Imaging, vol.14, issue.2, pp.293-300, 1995.
DOI : 10.1109/42.387711

G. Jacob, J. A. Noble, M. Mulet-parada, and A. Blake, Evaluating a robust contour tracker on echocardiographic sequences, Robust Contour Tracker on Echocardiographic Sequences, pp.63-75, 1999.
DOI : 10.1016/S1361-8415(99)80017-6

C. A. Pelizzari, G. T. Chen, D. R. Spelbring, R. R. Weichselbaum, and C. Chen, ªAccurate Three-Dimensional Registration of CT, PET, and/or MR Images of the Brain, ªA Method for Registration of 3D Shapes, pp.20-26, 1989.

J. Tsotsos, Knowledge organization and its role in representation and interpretation for time-varying data: the ALVEN system, Computational Intelligence, vol.38, issue.1, pp.16-32, 1985.
DOI : 10.1016/0146-664X(79)90075-3

J. Duncan, R. Owen, L. Staib, and P. , Anandan, ªMeasurement of Non-Rigid Motion Using Contour Shape Descriptors,º Computer Vision and Pattern Recognition, pp.318-324, 1991.

D. Metaxas and D. Terzopolous, ªConstrained Deformable Superquadrics and Nonrigid Motion Tracking,º Computer Vision and Pattern Recognition, pp.337-343, 1991.
DOI : 10.1109/cvpr.1991.139712

B. Horowitz and A. Pentland, ªRecovery of Nonrigid Motion and Structure,º Computer Vision and Pattern Recognition, pp.325-330, 1991.

J. Park, D. Metaxas, and L. Axel, ªAnalysis of Left Ventricular Wall Motion Based on Volumetric Deformable Models and MRI- SPAMM,º Medical Image Analysis, pp.53-71, 1996.

B. L. Holman, R. E. Zimmerman, K. A. Johnson, P. A. Carvalho, R. B. Schwartz et al., ªComputer-Assisted Superimposition of Magnetic Resonance and High Resolution Technetium-99m-HMPAO and Thal- lium-201 SPECT Images of the Brain, J. Nuclear Medicine, vol.32, issue.1, pp.478-1484, 1991.

P. Thompson, D. Macdonald, M. Mega, C. Holmes, and A. , Detection and Mapping of Abnormal Brain Structure with a Probabilistic Atlas of Cortical Surfaces, Journal of Computer Assisted Tomography, vol.21, issue.4, pp.567-581, 1997.
DOI : 10.1097/00004728-199707000-00008

D. Dean, P. Buckley, F. Bookstein, J. Kamath, D. Kwon et al., ªThree Dimensional MR-Based Morphometric Comparison of Schizophrenic and Normal Cerebral Ventricles,º Visualization in, pp.363-372, 1996.

L. D. Cohen and I. Cohen, ªFinite Element Methods for Active Contour Models and Balloons for 2D and 3D Images, IEEE Trans. Pattern Analysis and Machine Intelligence, vol.15147, issue.11 1, pp.131-132, 1993.

L. H. Staib and J. S. Duncan, ªModel-Based Deformable Surface Finding for Medical Images, IEEE Trans. Medical Imaging, vol.78, issue.5, pp.720-731, 1996.

T. F. Cootes, C. J. Taylor, D. H. Cooper, and J. Graham, Active Shape Models-Their Training and Application, Computer Vision and Image Understanding, vol.61, issue.1, pp.38-59, 1995.
DOI : 10.1006/cviu.1995.1004

G. S. Âly, A. Kelemen, C. Brechbu, È. , and G. Gerig, ªSegmentation of 3D Objects from MRI Volume Data Using Constrained Elastic Deformations of Flexible Fourier Surface Models,º Computer Vision, Virtual Reality, and Robotics in Medicine. N. Ayache, pp.495-505, 1995.

C. Xu and J. Prince, ªA Generalized Gradient Vector Flow for Active Contour Models, Proc. Conf. Information Sciences and Systems, pp.885-890, 1997.

S. Osher and J. Sethian, Fronts propagating with curvature-dependent speed: Algorithms based on Hamilton-Jacobi formulations, Journal of Computational Physics, vol.79, issue.1, pp.12-49, 1988.
DOI : 10.1016/0021-9991(88)90002-2

A. Yezzi, S. Kichenassamy, A. Kumar, P. Olver, and A. Tannenbaum, A geometric snake model for segmentation of medical imagery, IEEE Transactions on Medical Imaging, vol.16, issue.2, pp.199-209, 1997.
DOI : 10.1109/42.563665

URL : https://hal.archives-ouvertes.fr/hal-00002725

P. C. Teo, G. Sapiro, and B. A. , Creating connected representations of cortical gray matter for functional MRI visualization, IEEE Transactions on Medical Imaging, vol.16, issue.6, pp.852-863, 1997.
DOI : 10.1109/42.650881

R. Malladi, J. A. Sethian, and B. C. Vemuri, Shape modeling with front propagation: a level set approach, IEEE Transactions on Pattern Analysis and Machine Intelligence, vol.17, issue.2, pp.158-175, 1995.
DOI : 10.1109/34.368173

X. Zeng, L. H. Staib, R. T. Schultz, and J. S. Duncan, ªSegmentation and Measurement of the Cortex from 3D MR Images,º Medical Image Computing and Computer Assisted Intervention, pp.519-530, 1998.

L. Lorigo, O. Faugeras, W. Grimson, R. Keriven, R. Kikinis et al., Westin, ªCo-Dimension 2 Geodesic Active Contours for MRA Segmentation, Proc. Information Processing in Medical Imaging (IPMI), A. Kuba, M. Samal, and A. Todd-Pokropek, pp.126-139, 1999.
DOI : 10.1007/3-540-48714-x_10

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.32.1057

S. C. Zhu, T. S. Lee, and A. L. , Yuille, ªRegion Competition: Unifying Snakes, Region Growing and Bayes/MDL for Multi-Band Image Segmentation, Proc. Int'l Conf. Computer Vision, 1995.

A. Chakraborty, L. H. Staib, and J. S. Duncan, Deformable boundary finding in medical images by integrating gradient and region information, IEEE Transactions on Medical Imaging, vol.15, issue.6, pp.859-870, 1996.
DOI : 10.1109/42.544503

T. Cootes, C. Beeston, G. Edwards, and C. Taylor, ªA Unified Framework for Atlas Matching Using Active Appearance Models, Proc. Information Processing in Medical Imaging (IPMI99), pp.322-333, 1999.

W. M. Wells, W. Grimson, R. Kikinis, and F. A. , Jolesz, ªStatistical Intensity Correction and Segmentation of MRI Data, Proc. Visualization of Biomedical Computing, pp.148-159, 1994.

J. Sled, A. Zijdenbos, and A. Evans, A nonparametric method for automatic correction of intensity nonuniformity in MRI data, IEEE Transactions on Medical Imaging, vol.17, issue.1, pp.87-97, 1998.
DOI : 10.1109/42.668698

D. Pham and J. Prince, ªAn Adaptive Fuzzy Segmentation Algorithm for Three-Dimensional Magnetic Resonance Images,º Information Processing in Medical Imaging, pp.140-153, 1999.

D. L. Collins, A. P. Zijdenbos, V. Kollokian, J. G. Sled, N. J. Kabani et al., Design and construction of a realistic digital brain phantom, IEEE Transactions on Medical Imaging, vol.17, issue.3, pp.463-468, 1998.
DOI : 10.1109/42.712135

J. C. Rajapakse and F. Fruggel, ªSegmentation of MR Images with Intensity Inhomogeneities,º Image and Vision Computing, pp.165-180, 1998.

H. Jiang, K. Holton, and R. Robb, ªImage Registration of Multi- Modality 3-D Medical Images by Chamfer Matching, Proc. SPIE Biomedical Image Processing and Three-Dimensional Microscopy, pp.660-356, 1992.

R. A. Robb and D. P. Hanson, ªA Software System for Interactive and Quantitative Visualization of Multidimensional Biomedical Images,º Austalasian Physical and Eng, Sciences in Medicine, vol.14, pp.9-30, 1991.

J. Feldmar and N. Ayache, Rigid, affine and locally affine registration of free-form surfaces, International Journal of Computer Vision, vol.13, issue.2, pp.99-119, 1996.
DOI : 10.1007/BF00054998

URL : https://hal.archives-ouvertes.fr/inria-00074451

R. P. Woods, J. C. Mazziotta, and S. R. , MRI-PET Registration with Automated Algorithm, Journal of Computer Assisted Tomography, vol.17, issue.4, pp.536-546, 1993.
DOI : 10.1097/00004728-199307000-00004

W. Wells, I. , P. Viola, H. Atsumi, S. Nakajima et al., Multi-modal volume registration by maximization of mutual information, Medical Image Analysis, vol.1, issue.1, pp.35-52, 1996.
DOI : 10.1016/S1361-8415(01)80004-9

F. Maes, A. Collignon, D. Vandermeulen, G. Marchal, P. Suetens et al., ªMulti-Modality Image Registration by Maximization of Mutual Information,º IEEE Trans, ªSemiautomatic Registration of Volumetric Ultrasound Scans,º Ultrasound in Medicine and Biology, pp.187-198, 1997.

J. West, Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques, Journal of Computer Assisted Tomography, vol.21, issue.4, pp.554-566, 1997.
DOI : 10.1097/00004728-199707000-00007

URL : https://hal.archives-ouvertes.fr/inria-00615072

A. Roche, G. Malandain, X. Pennec, and N. Ayache, ªThe Correlation Ratio as a New Similarity Measure for Multimodal Image Registration, Proc. Medical Image Computing and Computer- Assisted Intervention, pp.115-116, 1998.

C. R. Meyer, J. L. Boes, B. Kim, P. Bland, K. R. Zasadny et al., Wahl, ªDemonstration of Accuracy and Clinical Versatility of Mutual Information for Automatic Multimodality Image Fusion Using Affine and Thin Plate Spline Warped Geometric Deformations, Medical Image Analysis, vol.3, pp.195-206, 1997.

F. Bookstein, ªShape and the Information in Medical Images: A Decade of the Morphometric Systhesis, Proc. Workshop Math. Methods in Medical Image Analysis, pp.2-12, 1996.

M. Vaillant and C. Davatzikos, ªFinding Parametric Representations of the Cortical Sulci Using an Active Contour Mode,lº Medical Image Analysis, pp.295-315, 1997.

B. Verdonck, R. Nijlunsing, J. Cheung, D. Wever, A. Veldhuizen et al., Makram-Ebeid, ªComputer Assisted Quantitative Analysis of Deformities of Human Spine,º Medical Image Computing and Computer Assisted Intervention, pp.822-831, 1998.

H. Benali, I. Buvat, J. Anton, M. Pelegrini, M. Dipaola et al., ªSpace-Time Statistical Model for Functional MR Image Sequences, Proc. Information Processing in Medical Imaging (IPMI), pp.285-298, 1997.

F. Kruggel and D. Von-cramon, ªPhysiologically Oriented Models of Hemodynamic Response in Functional MRI, Proc. Information Processing in Medical Imaging, pp.294-307, 1999.

E. Zerhouni, D. Parish, W. Rogers, A. Yang, and E. Shapiro, Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion., Radiology, vol.169, issue.1, pp.59-63, 1988.
DOI : 10.1148/radiology.169.1.3420283

L. Axel and L. Dougherty, MR imaging of motion with spatial modulation of magnetization., Radiology, vol.171, issue.3, pp.841-845, 1989.
DOI : 10.1148/radiology.171.3.2717762

W. Kerwin and J. Prince, Cardiac material markers from tagged MR images, ªCardiac Material Markers from Tagged MR Images, pp.339-354, 1998.
DOI : 10.1016/S1361-8415(98)80015-7

A. Amini, Y. Chen, R. Curwen, V. Mani, and J. Sun, Coupled B-snake grids and constrained thin-plate splines for analysis of 2-D tissue deformations from tagged MRI, IEEE Transactions on Medical Imaging, vol.17, issue.3, pp.344-356, 1998.
DOI : 10.1109/42.712124

S. N. Gupta and J. L. Prince, ªOn Variable Brightness Optical Flow for Tagged MRI,º Information Processing in Medical Imaging, pp.323-334, 1995.

R. T. Constable, K. Rath, A. Sinusas, and J. Gore, Development and evaluation of tracking algorithms for cardiac wall motion analysis using phase velocity MR imaging, Magnetic Resonance in Medicine, vol.2, issue.1, pp.33-42, 1994.
DOI : 10.1002/mrm.1910320106

F. Meyer, R. T. Constable, A. Sinusas, and J. Duncan, Tracking myocardial deformation using phase contrast MR velocity fields: a stochastic approach, IEEE Transactions on Medical Imaging, vol.15, issue.4, pp.453-465, 1996.
DOI : 10.1109/42.511749

C. Kambhamettu and D. Goldgof, ªCurvature-Based Approach to Point Correspondence Recovery in Conformal Nonrigid Motion,º CVGIP: Image Understanding, pp.26-43, 1994.

P. Shi, G. Robinson, R. Constable, A. Sinusas, and J. Duncan, ªA Model-Based, Integrated Approach to Track Myocardial Deformation Using Displacement and Velocity Constraints, Proc. Int'l Conf. Computer Vision, E. Grimson, pp.687-693, 1995.

S. Benayoun, C. Nastar, and N. Ayache, ªDense Non-Rigid Motion Estimation in Sequences of 3D Images Using Differential Constraints, Proc. Computer Vision, Virtual Reality, and Robotics in Medicine, pp.309-318, 1995.

G. Gerig, D. Welti, C. Guttmann, A. Colchester, and G. Szekely, ªExploring the Discrimination Power of the Time Domain for Segmentation and Characterization of Lesions in Serial MR Data, Proc. Medical Image Computing and Computer Assisted Intervention, pp.469-479, 1998.

D. Rey, G. Subsol, H. Delingette, and N. Ayache, ªAutomatic Detection and Segmentation of Evolving Processes in 3D Medical Images: Application to Multiple Sclerosis, Proc. Information Processing in Medical Imaging, IPMI 1999, pp.154-167, 1999.

M. Sallam and K. Bowyer, Registration and difference analysis of corresponding mammogram images, Medical Image Analysis, vol.3, issue.2, pp.103-118, 1999.
DOI : 10.1016/S1361-8415(99)80001-2

A. Mcculloch and J. Omens, Non-homogeneous analysis of three-dimensional transmural finite deformation in canine ventricular myocardium, Journal of Biomechanics, vol.24, issue.7, pp.539-548, 1991.
DOI : 10.1016/0021-9290(91)90287-W

E. Haber, D. Metaxas, and L. Axel, ªMotion Analysis of the Right Ventricle from MR Images, Proc. Medical Image Computing and Computer Assisted Intervention, pp.177-188, 1998.

S. Kyriacou and C. Davatzikos, ªA Biomechanical Model of Soft Tissue Deformation, with Applications to Non-Rigid Registration of Brain Images with Tumor Pathology,º Medical Image Computing and Computer Assisted Intervention, pp.531-538, 1998.

O. Skrinjar, D. Spencer, and J. Duncan, ªBrain Shift Modeling for Use in Neurosurgery, Proc. Medical Image Computing and Computer Assisted Intervention, pp.641-649, 1998.

M. Miga, K. Paulsen, F. Kennedy, J. Hoopes, A. Hartov et al., ªInitial in Vivo Analysis of 3D Heterogeneous Brain Computations for Model-Updated Image-Guided Neurosurgery, Proc. Medical Image Computing and Computer Assisted Intervention, W. Wells, A. Colchester, and S. Delp, pp.743-752, 1998.

R. Bucholz, R. Yeh, J. Trobaugh, L. Mcdurmont, C. Sturm et al., ªThe Correction of Stereotactic Inaccuracy Caused by Brain Shift Using an Intraoperative Ultrasound Device, Proc. Computer Vision, Virtual Reality and Robotics in Medicine-Medical Robotics and Computer Assisted Surgery, J. Troccaz, E. Grimson, and R. Mosges, pp.459-466, 1997.

P. Black, T. Moriarty, E. Alexander, P. Stieg, E. Woodard et al., Development and Implementation of Intraoperative Magnetic Resonance Imaging and Its Neurosurgical Applications, Neurosurgery, vol.41, issue.4, pp.831-845, 1997.
DOI : 10.1097/00006123-199710000-00013

W. Grimson, G. Ettinger, S. White, T. Lozano-perez, W. Wells et al., An automatic registration method for frameless stereotaxy, image guided surgery, and enhanced reality visualization, IEEE Transactions on Medical Imaging, vol.15, issue.2, pp.129-140, 1996.
DOI : 10.1109/42.491415

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.31.4271

C. Nikou and B. , Jaramaz, and A. DiGioia, ªRange of Motion after Total Hip Arthroplasty, Proc. Medical Image Computing and Computer Assisted Intervention, pp.700-709, 1998.

C. Nikou, B. Jaramaz, A. Digioia, M. Blackwell, M. Romesberg et al., ªPOP: Preoperative Planning and Simulation Software for Total Hip Replacement Surgery,º Medical Image Computing and Computer Assisted Intervention, pp.868-875, 1999.

A. Osborne and . Sawada, ªSimulating Arthroscopic Knee Surgery Using Volumetric Object Representations,º Proc Computer Vision, Virtual Reality and Robotics in Medicine-Medical Robotics and Computer Assisted Surgery, pp.369-378, 1997.

O. Wink, W. J. Niessen, and M. A. , Viergever, ªFast Quantification of Abdominal Aortic Aneurysms from CTA Volumes, Proc. Medical Image Computing and Computer Assisted Intervention, pp.138-145, 1998.

O. Wink, W. J. Niessen, J. J. Wever, I. A. Broeders, J. D. Blankensteijn et al., Viergever, ªSemi-Automated Quantification and Segmentation of Abdominal Aorta Aneurysms from CTA Volumes, Proc. Computer Assisted Radiology and Surgery (CARS 1999), pp.208-212, 1999.

T. Van-walsum and M. A. , Viergever, ªDeformable B-Splines for Catheter Simulation, Proc. Computer Assisted Radiology and Surgery (CARS 1999), p.999, 1999.

A. Colchester, J. Zhao, K. Holton-tainter, C. Henri, N. Maitland et al., Development and preliminary evaluation of VISLAN, a surgical planning and guidance system using intra-operative video imaging, Medical Image Analysis, vol.1, issue.1, pp.73-90, 1996.
DOI : 10.1016/S1361-8415(01)80006-2

R. A. Robb and D. P. Hanson, ªANALYZE: A Software System for Biomedical Image Analysis, Proc First Conf. Visualization Biomedical Computing, pp.507-518, 1990.

D. Atkinson, D. Hill, P. Stoyle, P. Summers, and S. Keevil, Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion, IEEE Transactions on Medical Imaging, vol.16, issue.6, pp.903-918, 1997.
DOI : 10.1109/42.650886

C. Meyer, P. Bland, and J. Pipe, Retrospective correction of intensity inhomogeneities in MRI, IEEE Transactions on Medical Imaging, vol.14, issue.1, pp.36-41, 1997.
DOI : 10.1109/42.370400

R. Highnam, M. Brady, and B. Shepstone, A representation for mammographic image processing, Medical Image Analysis, vol.1, issue.1, pp.1-18, 1996.
DOI : 10.1016/S1361-8415(01)80002-5

M. Insana and T. Hall, Parametric Ultrasound Imaging from Backscatter Coefficient Measurements: Image Formation and Interpretation, Ultrasonic Imaging, vol.10, issue.4, pp.245-267, 1990.
DOI : 10.1177/016173469001200402

B. Tsui, E. Frey, X. Zhao, D. Lalush, R. Johnson et al., The importance and implementation of accurate 3D compensation methods for quantitative SPECT, Physics in Medicine and Biology, vol.39, issue.3, pp.509-530, 1994.
DOI : 10.1088/0031-9155/39/3/015

P. Edwards, D. Hill, J. Little, and D. Hawkes, ªDeformation for Image Guided Intervention Using a Three Component Tissue Model 1993-1994 academic year. He is a member of Eta Kappa Nu and Sigma Xi, is on the editorial board of the Journal of Mathematical Imaging and Vision, is an associate editor for the IEEE Transactions on Medical Imaging, and is a coeditor-in-chief of the journal Medical Image Analysis he chaired the 15th international meeting on Information Processing in Medical Imaging, Proc. Information Processing in Medical Imaging he was elected to be a fellow of the American Institute for Medical and Biological Engineering (AIMBE). He is currently serving as a member of the diagnostic imaging study section at the National Institute of Health (NIH). Dr. Duncan is a senior member of the IEEE, pp.218-231, 1997.

. Dr, Ayache is the author of the books Artificial Vision for Mobile Robots and Vision ste Âre Âoscopique et perception multisensorielle (Inter- Editions) HeCVRMed) held in Nice in April 1995 and serves on the editorial boards of a number of conferences on medical imaging, computer vision, chaired the first International Conference on Computer Vision visualization and robotics including CVPR, ECCV, ICCV, and MICCAI. Dr. Ayache is a member of the IEEE