Monte Carlo simulations in SPET and PET Q, J. Nucl. Med, vol.46, pp.48-61, 2002. ,
Development and validation of a Monte Carlo simulation of photon transport in an Anger camera, IEEE Transactions on Medical Imaging, vol.9, issue.4, pp.430-468, 1990. ,
DOI : 10.1109/42.61758
Optimization of compact gamma cameras for breast imaging, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.471, issue.1-2, pp.222-230, 2001. ,
DOI : 10.1016/S0168-9002(01)00975-5
A 3D high resolution scintillation camera for radiopharmaceutical studies with small animals, Appl. Radiat. Isot, vol.58, pp.501-508, 1989. ,
Energy response and resolution of YAP :Ce matrix for imaging applications in nuclear medicine Nucl, Phys. B (Proc, pp.61-658, 1998. ,
Experimentally measured scatter fractions and energy spectra as a test of Monte Carlo simulations, Physics in Medicine and Biology, vol.32, issue.3, pp.335-378, 1987. ,
DOI : 10.1088/0031-9155/32/3/003
Technetium-99m-sestamibi uptake in breast tumor and associated lymph nodes, J. Nucl. Med, vol.37, pp.922-947, 1996. ,
Performance evaluation of A-SPECT: a high resolution desktop pinhole SPECT system for imaging small animals, IEEE Transactions on Nuclear Science, vol.49, issue.5, pp.2139-2186, 2002. ,
DOI : 10.1109/TNS.2002.803801
Scintillating array gamma camera for clinical use, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.392, issue.1-3, pp.295-303, 1997. ,
DOI : 10.1016/S0168-9002(97)00268-4
A pixelated 3D Auger camera with light-loss compensation, IEEE Transactions on Nuclear Science, vol.46, issue.4, pp.973-981, 1999. ,
DOI : 10.1109/23.790805
GATE, a Geant4-based simulation platform for PET integrating movement and time management, 2002 IEEE Nuclear Science Symposium Conference Record, pp.1516-1521, 2003. ,
DOI : 10.1109/NSSMIC.2002.1239563
URL : https://hal.archives-ouvertes.fr/in2p3-00012854
High-resolution scintimammography improves the accuracy of technetium-99m methoxyisobutylisonitrile scintimammography: use of a new dedicated gamma camera, European Journal of Nuclear Medicine and Molecular Imaging, vol.26, issue.10, pp.1279-88, 1999. ,
DOI : 10.1007/s002590050584
Geant4 Application fot Tomographic Emission): a PET/SPECT general purpose simulation platform, GATE Nucl. Phys. B (Proc, pp.125-75, 2003. ,
Comparison between YAP:Ce and CsI(Tl) multipillar matrices, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.418, issue.2-3, pp.497-506, 1998. ,
DOI : 10.1016/S0168-9002(98)00763-3
A study on light collection of small scintillating crystals, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.452, issue.1-2, pp.245-51, 2000. ,
DOI : 10.1016/S0168-9002(00)00434-4
A simulation to model position encoding multicrystal PET detectors, IEEE Transactions on Nuclear Science, vol.42, issue.6, pp.2236-2279, 1995. ,
DOI : 10.1109/23.489420
Performance of a PSPMT based detector for scintimammography, Physics in Medicine and Biology, vol.45, issue.3, pp.781-800, 2000. ,
DOI : 10.1088/0031-9155/45/3/315
Monte Carlo simulation in SPECT: complete 3D modeling of source, collimator and tomographic data acquisition, IEEE Transactions on Nuclear Science, vol.40, issue.2, pp.198-203, 1993. ,
DOI : 10.1109/23.212341
Comparative methods for quantifying thyroid volume using planar imaging and SPECT, J. Nucl. Med, vol.37, pp.1421-1447, 1996. ,
Relevance of accurate Monte Carlo modeling in nuclear medical imaging Med, Phys, vol.26, pp.574-608, 1999. ,
Comparative evaluation of photon cross-section libraries for materials of interest in PET Monte Carlo simulations, IEEE Transactions on Nuclear Science, vol.47, issue.6, pp.2722-2757, 2000. ,
DOI : 10.1109/23.901179