Skip to Main content Skip to Navigation
Journal articles

Perfluorocarbons and their use in cooling systems for semiconductor particle detectors

Abstract : We report on the development of evaporative fluorocarbon cooling for the semiconductor pixel and micro-strip sensors of inner tracking detector of the ATLAS experiment at the future CERN large hadron collider (LHC). We proceeded with studies using perfluoro-n-propane (3M-"PFG 5030"; C3F8), perfluoro-n-butane (3M-"PFG 5040"; C4F10), trifluoro-iodo-methane (CF3I) and custom C3F8/C4F10 mixtures. Certain thermo-physical properties had to be verified for these fluids. Sound velocity was calculated for the pure fluids and custom mixtures. A sonar instrument was developed for the measurement of sound velocity in the above fluids at a variety of temperatures and pressures. Irradiation studies were made on the fluids using neutrons and gamma rays to determine their suitability for use in the high radiation environment at LHC.
Complete list of metadata

http://hal.in2p3.fr/in2p3-00011261
Contributor : Magali Damoiseaux Connect in order to contact the contributor
Submitted on : Monday, March 11, 2002 - 11:53:27 AM
Last modification on : Tuesday, October 19, 2021 - 10:50:09 PM

Identifiers

  • HAL Id : in2p3-00011261, version 1

Collections

Citation

V. Vacek, G. Hallewell, S. Ilie, S. Lindsay. Perfluorocarbons and their use in cooling systems for semiconductor particle detectors. Fluid Phase Equilibria, Elsevier, 2000, 174, pp.191-201. ⟨in2p3-00011261⟩