Skip to Main content Skip to Navigation
New interface
Journal articles

In vivo measurement of breast tissues stiffness using a light aspiration device

Noémie Briot 1 Grégory Chagnon 1 Nathanaël Connesson 1 Yohan Payan 1 
1 TIMC-BIOMÉCA - Biomécanique des Tissus Vivants et des Matériaux – Modélisation et Caractérisation
TIMC - Translational Innovation in Medicine and Complexity / Recherche Translationnelle et Innovation en Médecine et Complexité - UMR 5525
Abstract : Background: This paper addresses the question of the in vivo measurement of breast tissue stiffness, which has been poorly adressed until now, except for elastography imaging which has shown promising results but which is still difficult for clinicians to use on a day-today basis. Estimating subject-specific tissue stiffness is indeed a critical area of research due to the development of a large number of Finite Element (FE) breast models for various medical applications. Methods: This paper proposes to use an original aspiration device, put into contact with breast surface, and to estimate tissue stiffness using an inverse analysis of the aspiration experiment. The method assumes that breast tissue is composed of a bilayered structure made of fatty and fribroglandular tissues (lower layer) superimposed with the skin (upper layer). Young moduli of both layers are therefore estimated based on 20 repeating low intensity suction tests (< 40mbar) of breast tissues using cups of 7 different diameters. Findings: Seven volunteers were involved in this pilot study with average Young moduli of 56.3 kPa ±16.4 and 3.04 kPa ±1.17 respectively for the skin and the fatty and fibroglandular tissue. The measurements were carried out in a reasonable time scale (< 60min in total) without any discomfort perceived by the participants. These encouraging results should be confirmed in a clinical study that will include a much larger number of volunteers and patients.
Complete list of metadata

https://hal.archives-ouvertes.fr/hal-03787504
Contributor : Yohan Payan Connect in order to contact the contributor
Submitted on : Sunday, September 25, 2022 - 1:16:43 PM
Last modification on : Tuesday, October 18, 2022 - 4:31:21 AM

File

2022 Briot - In vivo measureme...
Files produced by the author(s)

Identifiers

Collections

Citation

Noémie Briot, Grégory Chagnon, Nathanaël Connesson, Yohan Payan. In vivo measurement of breast tissues stiffness using a light aspiration device. Clinical Biomechanics, 2022, 99, pp.105743. ⟨10.1016/j.clinbiomech.2022.105743⟩. ⟨hal-03787504⟩

Share

Metrics

Record views

24

Files downloads

6