Optimization of image quality and accuracy of low iodine concentration quantification as function of kVp pairs for abdominal imaging using dual-source CT: A phantom study - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Physica Medica Année : 2021

Optimization of image quality and accuracy of low iodine concentration quantification as function of kVp pairs for abdominal imaging using dual-source CT: A phantom study

Résumé

Purpose: To determine the suitable kVp pair for optimal image quality of the virtual monochromatic images (VMIs) and iodine quantification accuracy at low concentration, using a third generation dual-source CT (DSCT).Materials and methods: Multi-energy CT phantoms with and without body rings were scanned with a DSCT using four kVp pairs (tube "A"/"B" voltage): 100/Sn150, 90/Sn150, 80/Sn150 and 70/Sn150 kVp. The reference mAs was adjusted to obtain a CTDIvol close to 11 mGy. HU values accuracy (RMSDHU), noise (SD) and contrast-to-noise ratio (CNR) of iodine inserts of 0.5, 1, 2 and 5 mg/mL concentrations were assessed on VMIs at 40/50/60/70 keV. Iodine quantification accuracy was assessed using the RMSDiodine and iodine bias (IBiodine).Results: The RMSDHU decreased when the tube "A" voltage increased. The mean noise value increased significantly with tube "A" voltage (p < 0.001) but decreased between 80/Sn150 and 90/Sn150 kVp for the small phantom (1.1 ± 0.1%; p = 0.047). The CNR significantly decreased with tube "A" voltage (p < 0.001), except between 80/Sn150 and 90/Sn150 kVp for all inserts and between 90/Sn150 kVp and 100/Sn150 kVp for the 1.0 and 0.5 mg/mL inserts in the large phantom. In the small phantom, no significant difference was found between 80/Sn150 kVp and 90/Sn150 kVp for all inserts and between 80/Sn150, 90/Sn150 and 100/Sn150 kVp for the 1 and 0.5 mg/mL inserts. The RMSDiodine and IBiodine decreased as the tube "A" voltage of the kVp pair increased.Conclusion:The kVp pair of 70/Sn150 led to better image quality in VMIs and sufficient iodine accuracy.
Fichier principal
Vignette du fichier
S1120179721002520.pdf (1.35 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03630648 , version 1 (22-08-2023)

Licence

Paternité - Pas d'utilisation commerciale

Identifiants

Citer

Djamel Dabli, Julien Frandon, Aymeric Hamard, Asmaa Belaouni, Takieddine Addala, et al.. Optimization of image quality and accuracy of low iodine concentration quantification as function of kVp pairs for abdominal imaging using dual-source CT: A phantom study. Physica Medica, 2021, 88, pp.285-292. ⟨10.1016/j.ejmp.2021.07.008⟩. ⟨hal-03630648⟩
49 Consultations
4 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More