Determination of L-X ray absolute emission intensities of $^{238}$Pu, $^{244}$Cm, $^{237}$Np and $^{233}$Pa radionuclides using a metallic magnetic calorimeter - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Spectrochimica Acta Part B: Atomic Spectroscopy Année : 2022

Determination of L-X ray absolute emission intensities of $^{238}$Pu, $^{244}$Cm, $^{237}$Np and $^{233}$Pa radionuclides using a metallic magnetic calorimeter

Résumé

Energy dispersive photon spectrometry is a common analysis technique to quantify radionuclides present in a sample, the analysis is based on the knowledge of the photon emission intensities specific to each radionuclide. Among them, actinides have in general intense emission of L X-rays during the decay. However, their emission intensities are not well known and not detailed in the nuclear and atomic data tables due to the complexity of their spectra that cannot be resolved by conventional semiconductor spectrometers. Using a dedicated high energy resolution cryogenic detector, based on metallic magnetic calorimeter sensor technology, the L X-ray spectra of the decays of 238Pu(α) → 234U, 244Cm(α) → 240Pu, 237Np(α) → 233Pa and 233Pa(β) → 233U were measured with an energy resolution between 23 eV and 43 eV (full width at half maximum) given access to an unprecedented level of detail. Moreover, the detector was conceived to provide a quasi-constant efficiency in the energy range of the L X-rays, minimizing the uncertainty for relative L X-ray emission intensities. Prior to the measurements, the full energy peak efficiency was carefully characterized, which enabled the determination of absolute emission intensities, with an uncertainty of the order of 1%. Some corrections had to be introduced using Monte Carlo simulations, in particular to take into account the surface activity inhomogeneities of the sources. Total and group L X-ray emission intensities are compared with the available data and with the recommended values. In addition, nearly 30 individual L X-ray intensities are presented. Unlabelled Image •Measurement of tens of L X-ray emission intensities emitted by actinides•A cryogenic spectrometer with an energy resolution of 23 to 43 eV•An intrinsic efficiency close to 100% between 10 keV and 25 keV•Detailed uncertainty contributions from the efficiency and the sources•Comparison of the measured intensities with available data
Fichier principal
Vignette du fichier
article_RihamMariam_SAPB-D-21-00155.pdf (2.11 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03554683 , version 1 (03-02-2022)

Identifiants

Citer

Riham Mariam, Matias Rodrigues, Martin Loidl, Sylvie Pierre, Valérie Lourenço. Determination of L-X ray absolute emission intensities of $^{238}$Pu, $^{244}$Cm, $^{237}$Np and $^{233}$Pa radionuclides using a metallic magnetic calorimeter. Spectrochimica Acta Part B: Atomic Spectroscopy, 2022, 187, pp.106331. ⟨10.1016/j.sab.2021.106331⟩. ⟨hal-03554683⟩
97 Consultations
4 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More