Experience Influences the Agreement and Reliability of Tibial Component Positioning in Total Knee Arthroplasty. - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue The Journal of Arthroplasty Année : 2018

Experience Influences the Agreement and Reliability of Tibial Component Positioning in Total Knee Arthroplasty.

Derek F. Amanatullah
  • Fonction : Auteur
Graham D. Pallante
  • Fonction : Auteur
Alexander W. Hooke
  • Fonction : Auteur
Matthew P. Abdel
  • Fonction : Auteur
Michael J. Taunton
  • Fonction : Auteur

Résumé

BACKGROUND: Poor rotation of the tibial component is associated with unfavorable total knee arthroplasty outcomes. Some surgeons utilize the tibial tubercle (TT method), while others utilize the femoral cam (Box method) as a rotational landmark during total knee arthroplasty. Our purpose is to determine the reproducibility of 2 methods for establishing intra-operative tibial component rotation, while also comparing the effect of level of training. METHODS: Twelve surgeons positioned and sized a symmetric tibial component on 7 cadaver knees. Surgeons were allowed to utilize their preferred method for establishing tibial component rotation. Seven surgeons selected the TT method, 4 utilized the Box method, and 1 used both methods depending on the specimen. Repeat measurements were completed by each surgeon after a rest period. The differences between tibial tray positions were assessed using computer-assisted optoelectronic measurements. Intra-class correlation coefficients were calculated to determine inter-observer agreement (IOA) and intra-rater reliability (IRR). RESULTS: Overall, both the Box method and the TT method demonstrated high IRR for tibial component rotation. Experienced surgeons were more consistent at establishing component rotation regardless of technique. Trainees were more consistent when utilizing the Box method (IRR 0.96, IOA 0.94) than the TT method (IRR 0.71, IOA 0.72). CONCLUSION: Surgeon experience influences the agreement and reliability of tibial component position. For less experienced surgeons, the Box method was more effective than the TT method for consistently reproducing tibial component rotation.
Fichier non déposé

Dates et versions

hal-03551882 , version 1 (02-02-2022)

Identifiants

Citer

Derek F. Amanatullah, Graham D. Pallante, Matthieu P. Ollivier, Alexander W. Hooke, Matthew P. Abdel, et al.. Experience Influences the Agreement and Reliability of Tibial Component Positioning in Total Knee Arthroplasty.. The Journal of Arthroplasty, 2018, 33 (4), pp.1231--1234. ⟨10.1016/j.arth.2017.11.012⟩. ⟨hal-03551882⟩
15 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More