Equivalent Model and Control of a Neutral Point Supply SynRM Drive - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2020

Equivalent Model and Control of a Neutral Point Supply SynRM Drive

Résumé

Three-phase AC motors fed by the neutral point supply (NPS) topology integrate a DC/DC converter function. In order to clearly explain the mechanism of the integrated DC/DC converter function, the average model and an equivalent circuit of the special topology are developed. Then, a new control strategy is proposed for the topology, in which the motor and the DC-link voltage can be independently controlled. Experiments are implemented on a 1.5 kW synchronous reluctance motor to verify the correctness of these theoretical analyses and the effectiveness of the proposed control strategy.
Fichier non déposé

Dates et versions

hal-03530940 , version 1 (17-01-2022)

Identifiants

Citer

Xiaokang Zhang, Jean-Yves Gauthier, Xuefang Lin-Shi. Equivalent Model and Control of a Neutral Point Supply SynRM Drive. EPE'20 ECCE Europe, Sep 2020, Lyon, France. pp.1-8, ⟨10.23919/EPE20ECCEEurope43536.2020.9215855⟩. ⟨hal-03530940⟩
37 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More