Does a combined screw and dowel construct improve tibial fixation during anterior cruciate ligament reconstruction? - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue European Journal of Orthopaedic Surgery & Traumatology: Orthopedie Traumatologie Année : 2021

Does a combined screw and dowel construct improve tibial fixation during anterior cruciate ligament reconstruction?

Résumé

Purpose: The aims of the present study were to compare the biomechanical properties of tibial fixation in hamstring-graft ACL reconstruction using interference screw and a novel combination interference screw and dowel construct. Material and methods: We compared the fixation of 30 (2- and 4-stranded gracilis and semitendinosis tendons) in 15 fresh-frozen porcine tibiae with a biocomposite resorbable interference screw (Group 1) and a screw and dowel construct (Group 2). Each graft was subjected to load-to-failure testing (50 mm/min) to determine maximum load, displacement at failure and pullout strength. Results: There were no significant differences between the biomechanical properties of the constructs. Multivariate analysis demonstrated that combination constructs (β = 140.20, p = 0.043), screw diameter (β = 185, p = 0.006) and 4-strand grafts (β = 51, p = 0.050) were associated with a significant increase in load at failure. Larger screw diameter was associated with increased construct stiffness (β = 20.15, p = 0.020). Conclusion: The screw and dowel construct led to significantly increased fixation properties compared to interference screws alone in a porcine model. Increased screw diameter and utilization of 4-strand ACL grafts also led to improvement in load-to-failure of the construct. However, this is an in vitro study and additional investigations are needed to determine whether the results are reproducible in vivo. Level of evidence: Level V; Biomechanical study.
Fichier principal
Vignette du fichier
Laumonerle_28016.pdf (529.92 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03382450 , version 1 (18-10-2021)

Identifiants

Citer

Pierre Laumonerie, Meagan E. Tibbo, Gregoire Laumond, Dominique Barbier, Pauline Assemat, et al.. Does a combined screw and dowel construct improve tibial fixation during anterior cruciate ligament reconstruction?. European Journal of Orthopaedic Surgery & Traumatology: Orthopedie Traumatologie, 2021, pp.0. ⟨10.1007/s00590-021-03049-2⟩. ⟨hal-03382450⟩
15 Consultations
50 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More