Biomagnetic Monitoring vs. CFD Modeling: A Real Case Study of Near-Source Depositions of Traffic-Related Particulate Matter along a Motorway - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Atmosphere Année : 2020

Biomagnetic Monitoring vs. CFD Modeling: A Real Case Study of Near-Source Depositions of Traffic-Related Particulate Matter along a Motorway

Sarah Letaïef
  • Fonction : Auteur
  • PersonId : 1095320
Pierre Camps
Thierry Poidras
  • Fonction : Auteur
  • PersonId : 828410
Patrick Nicol
  • Fonction : Auteur
  • PersonId : 862989
Delphine Bosch
Romane Pradeau
  • Fonction : Auteur
  • PersonId : 1095321

Résumé

A test site located along a 12-lane motorway east of Montpellier, France, is used to evaluate the potential of biomagnetic monitoring on traffic-related particulate matter (PM) to parametrize a computational fluid dynamics (CFD) simulation of the local airflow. Two configurations were established on the site with three vegetated flat-top earth berms of a basic design, and a fourth one was located windward to the traffic roofed with a 4-m-high precast concrete wall. As a first step, PM deposition simultaneously on plant leaves, on low-cost passive artificial filters, and on soils was estimated from proxies supplied by magnetic and X-ray fluorescence measurements on both sides of the motorway. These latter revealed that traffic-related pollutants are present on soils samples highlighted with a clear fingerprint of combustion residues, and wears of breaks, vehicles, and highway equipment. Maximum PM accumulations were detected in the lee of the berm-wall combination, while no significant deposition was observed on both sides of the flat-top earth berms. These results are in line with measurements from PM µ-sensors operated by the regional stateapproved air quality agency. Finally, we compared the experimental measurements with the outcomes of a computational fluid dynamics (CFD) modeling based on the Reynolds-Averaged Navier-Stokes (RANS) equations that consider the traffic-induced momentum and turbulence. The CFD modeling matches the experimental results by predicting a recirculated flow in the near wake of the berm-wall combination that enhances the PM concentration, whereas the flat-top berm geometry does not alter the pollutants' transport and indeed contributes to their atmospheric dispersion.
Fichier principal
Vignette du fichier
atmosphere-Vers-HAL.pdf (8.34 Mo) Télécharger le fichier
image.jpg (2.42 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03189791 , version 1 (06-04-2021)

Licence

Paternité

Identifiants

Citer

Sarah Letaïef, Pierre Camps, Thierry Poidras, Patrick Nicol, Delphine Bosch, et al.. Biomagnetic Monitoring vs. CFD Modeling: A Real Case Study of Near-Source Depositions of Traffic-Related Particulate Matter along a Motorway. Atmosphere, 2020, Air Pollution and Environment in France, 11 (12), pp.1285. ⟨10.3390/atmos11121285⟩. ⟨hal-03189791⟩
840 Consultations
31 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More