Void fraction influence on CICCs coupling losses: analysis of experimental results with MPAS model - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue IEEE Transactions on Applied Superconductivity Année : 2020

Void fraction influence on CICCs coupling losses: analysis of experimental results with MPAS model

Résumé

Modelling by analytical approach the coupling losses of CICCs used in tokamaks remains a challenge to be reliable. This is usually done using either CPU consuming numerical approaches or heuristic models such as MPAS now used for ITER. Experimental measurements of AC losses are performed at CEA using magnetization method on several type of JT-60SA TF samples with various void fractions (25%-36%). Influence of void fraction on coupling losses is hard to heuristically model yet. We choose to develop an experimental protocol in order to measure coupling losses in a range of frequency relevant to the domain of operation of fusion magnet. AC losses model as MPAS is confronted to our JOSEFA experimental data.Conclusion and lessons will be taken into account for future work.
Fichier principal
Vignette du fichier
MT26_Paper_13-09-2019_CHILETTI_V7.pdf (467.97 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03086183 , version 1 (22-02-2023)

Identifiants

Citer

Maxime Chiletti, Jean-Luc Duchateau, Frédéric Topin, Bernard Turck, Louis Zani. Void fraction influence on CICCs coupling losses: analysis of experimental results with MPAS model. IEEE Transactions on Applied Superconductivity, 2020, 30 (4), pp.4701405. ⟨10.1109/TASC.2020.2972861⟩. ⟨hal-03086183⟩
35 Consultations
17 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More