Method for High Frequency Underway N-2 Fixation Measurements: Flow-Through Incubation Acetylene Reduction Assays by Cavity Ring Down Laser Absorption Spectroscopy (FARACAS) - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Analytical Chemistry Année : 2018

Method for High Frequency Underway N-2 Fixation Measurements: Flow-Through Incubation Acetylene Reduction Assays by Cavity Ring Down Laser Absorption Spectroscopy (FARACAS)

Résumé

Because of the difficulty in resolving the large variability of N-2 fixation with current methods which rely on discrete sampling, the development of new methods for high resolution measurements is highly desirable. We present a new method for high-frequency measurements of aquatic N-2 fixation by continuous flow-through incubations and spectral monitoring of the acetylene (C2H2, a substrate analog for N-2) reduction to ethylene (C2H4). In this method, named Flow-through Incubation Acetylene Reduction Assays by Cavity Ring-Down Laser Absorption Spectroscopy (FARACAS), dissolved C2H2 is continuously admixed with seawater upstream of a continuous flow stirred-tank reactor (CFSR) in which C2H2 reduction takes place. Downstream of the flow-through incubator, the C2H4 gas is stripped using a bubble column contactor and circulated with a diaphragm pump into a wavelength-scanned cavity ring down laser absorption spectrometer (CRDS). Our method provides high-resolution and precise mapping of aquatic N-2 fixation, its diel cycle, and its response to environmental gradients, and can be adapted to measure other biological processes. The short-duration of the flow-through incubations without preconcentration of cells minimizes potential artifacts such as bottle containment effects while providing near real-time estimates for adaptive sampling. We expect that our new method will improve the characterization of the biogeography and kinetics of aquatic N-2 fixation rates.
Fichier principal
Vignette du fichier
Cassar_etal_AC_2018.pdf (5.66 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-02619273 , version 1 (25-05-2020)

Identifiants

Citer

Nicolas Cassar, Weiyi Tang, Hans Gabathuler, Kuan Huang. Method for High Frequency Underway N-2 Fixation Measurements: Flow-Through Incubation Acetylene Reduction Assays by Cavity Ring Down Laser Absorption Spectroscopy (FARACAS). Analytical Chemistry, 2018, 90 (4), pp.2839-2851. ⟨10.1021/acs.analchem.7b04977⟩. ⟨hal-02619273⟩
52 Consultations
39 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More