Impact of the transformer in the current mode supply of dielectric barrier discharge excimer lamps - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2013

Impact of the transformer in the current mode supply of dielectric barrier discharge excimer lamps

David Florez
Xavier Bonnin
Rafael Diez
Hubert Piquet

Résumé

This paper presents an analysis of the consequences of using a step-up transformer in the supply of a dielectric barrier discharge (DBD) excimer lamp. A simplified transformer model is used to analyze the effects of the different parasitic elements in the operation of a current mode power supply. Mathematical expressions are found for each element and experimental validation is performed. The design of the transformer is developed on the basis of the lamp specifications and two transformer configurations are tested experimentally, analyzing the effect of the parasitic elements and evidencing the influence of grounding a lamp terminal
Fichier non déposé

Dates et versions

hal-02515187 , version 1 (23-03-2020)

Identifiants

Citer

David Florez, Xavier Bonnin, Rafael Diez, Hubert Piquet. Impact of the transformer in the current mode supply of dielectric barrier discharge excimer lamps. 2013 Brazilian Power Electronics Conference (COBEP 2013), Oct 2013, Gramado, Brazil. pp.1171-1176, ⟨10.1109/COBEP.2013.6785263⟩. ⟨hal-02515187⟩
23 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More