Progress on the PICOSEC-Micromegas Detector Development: Towards a precise timing, radiation hard, large-scale particle detector with segmented readout - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2020

Progress on the PICOSEC-Micromegas Detector Development: Towards a precise timing, radiation hard, large-scale particle detector with segmented readout

K. Kordas
  • Fonction : Auteur
J. Bortfeldt
  • Fonction : Auteur
F. Brunbauer
  • Fonction : Auteur
C. David
G. Fanourakis
  • Fonction : Auteur
J. Franchi
  • Fonction : Auteur
M. Gallinaro
  • Fonction : Auteur
F. García
  • Fonction : Auteur
D. González-Díaz
  • Fonction : Auteur
J. Liu
  • Fonction : Auteur
M. Lupberger
  • Fonction : Auteur
I. Maniatis
  • Fonction : Auteur
I. Manthos
  • Fonction : Auteur
H. Müller
  • Fonction : Auteur
V. Niaouris
  • Fonction : Auteur
E. Oliveri
  • Fonction : Auteur
K. Paraschou
  • Fonction : Auteur
B. Qi
  • Fonction : Auteur
F. Resnati
  • Fonction : Auteur
L. Ropelewski
  • Fonction : Auteur
D. Sampsonidis
  • Fonction : Auteur
T. Schneider
  • Fonction : Auteur
M. van Stenis
  • Fonction : Auteur
P. Thuiner
  • Fonction : Auteur
Y. Tsipolitis
  • Fonction : Auteur
S.E. Tzamarias
  • Fonction : Auteur
R. Veenhof
  • Fonction : Auteur
X. Wang
  • Fonction : Auteur
S. White
  • Fonction : Auteur
Z. Zhang
Y. Zhou
  • Fonction : Auteur

Résumé

This contribution describes the PICOSEC-Micromegas detector which achieves a time resolution below 25 ps. In this device the passage of a charged particle produces Cherenkov photons in a radiator, which then generate electrons in a photocathode and these photoelectrons enter a two-stage Micromegas with a reduced drift region and a typical anode region. The results from single-channel prototypes (demonstrating a time resolution of 24 ps for minimum ionizing particles, and 76 ps for single photoelectrons), the understanding of the detector in terms of detailed simulations and a phenomenological model, the issues of robustness and how they are tackled, and preliminary results from a multi-channel prototype are presented (demonstrating that a timing resolution similar to that of the single-channel device is feasible for all points across the area covered by a multi-channel device).

Dates et versions

hal-02507894 , version 1 (13-03-2020)

Identifiants

Citer

K. Kordas, J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, et al.. Progress on the PICOSEC-Micromegas Detector Development: Towards a precise timing, radiation hard, large-scale particle detector with segmented readout. 15th Vienna Conference on Instrumentation, Feb 2019, Vienna, Austria. pp.162877, ⟨10.1016/j.nima.2019.162877⟩. ⟨hal-02507894⟩