Comparative Assessment of a Commercial Kit and Two Laboratory-Developed PCR Assays for Molecular Diagnosis of Congenital Toxoplasmosis - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Journal of Clinical Microbiology Année : 2012

Comparative Assessment of a Commercial Kit and Two Laboratory-Developed PCR Assays for Molecular Diagnosis of Congenital Toxoplasmosis

Résumé

Toxoplasmosis is a worldwide infection that may cause severe disease and is regarded as a serious health problem in France. Detection of the parasite by molecular methods is crucial for diagnosing the disease. The extreme diversity of methods and performances of Toxoplasma PCR assays makes the use of commercial PCR kits an attractive alternative, as they offer a chance for standardization. We compared the performances of three molecular methods for the detection of Toxoplasma gondii DNA in amniotic fluid: a commercial method using nested PCR and two laboratory-developed methods, one using conventional PCR and the other one real-time PCR. This evaluation was based upon a T. gondii DNA serial dilution assay, three amniotic fluid samples spiked with T. gondii at different concentrations, and a clinical cohort of 33 amniotic fluid samples. The T. gondii DNA serial dilution assay showed a much lower sensitivity for the commercial kit than for the laboratory-developed methods. Moreover, out of 12 proven congenital toxoplasmosis cases, 91.7% were detected by the laboratory-developed assays, whereas only 50% were detected by the commercial kit. A lack of sensitivity of the method, partly due to the presence of PCR inhibitors, was the main drawback of the commercial method. This study emphasizes that commercial PCR diagnostic kits do not systematically perform better than carefully optimized laboratory-developed methods. There is a need for thorough evaluation of such kits by proficient groups, as well as for performance standards that commercial kits can be tested against to improve confidence in those selected by health care providers.

Dates et versions

hal-02421333 , version 1 (20-12-2019)

Identifiants

Citer

C. Morelle, E. Varlet-Marie, M.-P. Brenier-Pinchart, S. Cassaing, H. Pelloux, et al.. Comparative Assessment of a Commercial Kit and Two Laboratory-Developed PCR Assays for Molecular Diagnosis of Congenital Toxoplasmosis. Journal of Clinical Microbiology, 2012, 50 (12), pp.3977-3982. ⟨10.1128/JCM.01959-12⟩. ⟨hal-02421333⟩
23 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More