Inductances Estimation in the d-q Axis for an Interior Permanent-Magnet Synchronous Machines with Distributed Windings - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Journal of Energy and Power Engineering Année : 2013

Inductances Estimation in the d-q Axis for an Interior Permanent-Magnet Synchronous Machines with Distributed Windings

Résumé

The inductances in d-q axis have an important influence on the behavior of PMSM (PM (permanent-magnet) synchronous machines). Their calculation is fundamental not only to evaluate the performance such as torque and field weakening capability but also to design the control system to maximize performance and power factor. This paper presents a study of inductance in the d-q axis for buried (i.e., IPMSM (interior) PM Synchronous Machines). This study is achieved using 2-D (two-dimensional) FEM (finite-element method) and Park’s transformation.
Fichier non déposé

Dates et versions

hal-02300079 , version 1 (29-09-2019)

Identifiants

  • HAL Id : hal-02300079 , version 1

Citer

Abdessamed Soualmi, Frédéric Dubas, Daniel Depernet, Andry Randria, Christophe Espanet. Inductances Estimation in the d-q Axis for an Interior Permanent-Magnet Synchronous Machines with Distributed Windings. Journal of Energy and Power Engineering, 2013, 7, pp.1178 - 1185. ⟨hal-02300079⟩
32 Consultations
0 Téléchargements

Partager

Gmail Facebook X LinkedIn More