Correcting the extended-source calibration for the Herschel-SPIRE Fourier-transform spectrometer - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Monthly Notices of the Royal Astronomical Society Année : 2018

Correcting the extended-source calibration for the Herschel-SPIRE Fourier-transform spectrometer

I. Valtchanov
  • Fonction : Auteur
C Benson
  • Fonction : Auteur
N Lu
  • Fonction : Auteur
N Marchili
  • Fonction : Auteur
G Makiwa
  • Fonction : Auteur
R Meyer
  • Fonction : Auteur
D Naylor
  • Fonction : Auteur
C North
  • Fonction : Auteur
A Papageorgiou
  • Fonction : Auteur
C Pearson
  • Fonction : Auteur
E Polehampton
  • Fonction : Auteur
J Scott
  • Fonction : Auteur
L Spencer
  • Fonction : Auteur
M. van Der Wiel
  • Fonction : Auteur

Résumé

We describe an update to the Herschel-Spectral and Photometric Imaging Receiver (SPIRE) Fourier-transform spectrometer (FTS) calibration for extended sources, which incorporates a correction for the frequency-dependent far-field feedhorn efficiency, ηff. This significant correction affects all FTS extended-source calibrated spectra in sparse or mapping mode, regardless of the spectral resolution. Line fluxes and continuum levels are underestimated by factors of 1.3–2 in thespectrometer long wavelength band (447–1018 GHz; 671–294 μm) and 1.4–1.5 in the spectrometer short wavelength band (944–1568 GHz; 318–191 μm). The correction was implemented in the FTS pipeline version 14.1 and has also been described in the SPIRE Handbook since 2017 February. Studies based on extended-source calibrated spectra produced prior to this pipeline version should be critically reconsidered using the current products available in the Herschel Science Archive. Once the extended-source calibrated spectra are corrected for ηff, the synthetic photometry and the broad-band intensities from SPIRE photometer maps agree within 2–4 per cent – similar levels to the comparison of point-source calibrated spectra and photometry from point-source calibrated maps. The two calibration schemes for the FTS are now self-consistent: the conversion between the corrected extended-source and point-source calibrated spectra can be achieved with the beam solid angle and a gain correction that accounts for the diffraction loss.
Fichier principal
Vignette du fichier
stx3178.pdf (1.36 Mo) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-02294178 , version 1 (04-05-2023)

Identifiants

Citer

I. Valtchanov, R. Hopwood, G. Bendo, C Benson, L. Conversi, et al.. Correcting the extended-source calibration for the Herschel-SPIRE Fourier-transform spectrometer. Monthly Notices of the Royal Astronomical Society, 2018, 475 (1), pp.321-330. ⟨10.1093/mnras/stx3178⟩. ⟨hal-02294178⟩
45 Consultations
10 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More