, The polymer solution was mixed on a rollerbank for at least 48 h and degassed for 24 h before the spinning process. The polymer solutions were pumped through the spinneret using a speed of 1 mL/min at room temperature (the dimensions of the spinneret are listed in Table C1 below). To create the bore, ultrapure water was pumped through the spinneret with a speed of 5.8 mL/min, PES-SS2 hollow fiber membranes were prepared by dry-wet spinning via immersion precipitation. First, 15 wt% PES was dissolved in NMP and then 2 wt% SS was added

M. S. Tijink, Mixed matrix hollow fiber membranes for removal of proteinbound toxins from human plasma, Biomaterials, vol.34, issue.32, pp.7819-7828, 2013.

M. Tijink, Development of novel membranes for blood purification therapies based on copolymers of N-vinylpyrrolidone and n-butylmethacrylate, J. Mater. Chem. B, vol.1, issue.44, pp.6066-6077, 2013.

R. Vanholder, Review on uremic toxins: classification, concentration, and interindividual variability, Kidney Int, vol.63, issue.5, pp.1934-1943, 2003.

A. Davenport, Portable and wearable dialysis devices for the treatment of patients with end-stage kidney failure: Wishful thinking or just over the horizon?, Pediat. Nephrol, vol.30, issue.12, pp.2053-2060, 2014.

A. Davenport, A wearable haemodialysis device for patients with end-stage renal failure: a pilot study, Lancet, vol.370, issue.9604, pp.2005-2010, 2007.

W. H. Fissell, S. Roy, and A. Davenport, Achieving more frequent and longer dialysis for the majority: wearable dialysis and implantable artificial kidney devices, Kidney Int, vol.84, issue.2, pp.256-264, 2013.

S. Eloot, I. Ledebo, and R. A. Ward, Extracorporeal removal of uremic toxins: can we still do better?, Semin. Nephrol, vol.34, issue.2, pp.209-227, 2014.

V. Gura, Continuous renal replacement therapy for end-stage renal diseaseThe wearable artificial kidney (WAK), Cardiovasc. Disorders Hemodial, vol.149, pp.325-333, 2005.

H. Susanto and M. Ulbricht, Characteristics, performance and stability of polyethersulfone ultrafiltration membranes prepared by phase separation method using different macromolecular additives, J. Membr. Sci, vol.327, issue.1-2, pp.125-135, 2009.

M. Teodorescu and M. Bercea, Poly(vinylpyrrolidone) -a versatile polymer for biomedical and beyond medical applications, Polym.-Plast. Technol. Eng, vol.54, issue.9, pp.923-943, 2015.

S. Q. Nie, Improved blood compatibility of polyethersulfone membrane with a hydrophilic and anionic surface, Colloids Surfaces B-Biointerfaces, vol.100, pp.116-125, 2012.

Y. L. Su, Modification of polyethersulfone ultrafiltration membranes with phosphorylcholine copolymer can remarkably improve the antifouling and permeation properties, J. Membr. Sci, vol.322, issue.1, pp.171-177, 2008.

Y. Koga, Biocompatibility of polysulfone hemodialysis membranes and its mechanisms: involvement of fibrinogen and its integrin receptors in activation of platelets and neutrophils, Artif. Organs, vol.42, issue.9, pp.246-258, 2018.

M. Matsuda, Effects of fluid flow on elution of hydrophilic modifier from dialysis membrane surfaces, J. Artif. Organs, vol.11, issue.3, pp.148-155, 2008.

K. Namekawa, Poly(N-vinyl-2-pyrrolidone) elution from polysulfone dialysis membranes by varying solvent and wall shear stress, J. Artif. Organs, vol.15, issue.2, pp.185-192, 2012.

B. Madsen, Effect of sterilization techniques on the physicochemical properties of polysulfone hollow fibers, J. Appl. Polym. Sci, vol.119, issue.6, pp.3429-3436, 2011.

W. Albrecht, Modification of poly(ether imide) membranes with brominated polyvinylpyrrolidone, J. Membr. Sci, vol.291, issue.1-2, pp.10-18, 2007.

M. Miyata, Influence of sterilization and storage period on elution of polyvinylpyrrolidone from wet-type polysulfone membrane dialyzers, Asaio J, vol.61, issue.4, pp.468-473, 2015.

K. Namekawa, Longer storage of dialyzers increases elution of poly(N-vinyl-2-pyrrolidone) from polysulfone-group dialysis membranes, J. Artif. Organs, vol.14, issue.1, pp.52-57, 2011.

X. L. Liu, Poly(N-vinylpyrrolidone)-modified surfaces for biomedical applications, Macromol. Biosci, vol.13, issue.2, pp.147-154, 2013.

S. Konishi, Eluted substances from hemodialysis membranes elicit positive skin prick tests in bioincompatible patients, Artif. Organs, vol.39, issue.4, pp.343-351, 2015.

N. Nady, Modification methods for poly(arylsulfone) membranes: A minireview focusing on surface modification, Desalination, vol.275, issue.1-3, pp.1-9, 2011.

C. He, Graphene oxide and sulfonated polyanion co-doped hydrogel films for dual-layered membranes with superior hemocompatibility and antibacterial activity, Biomater. Sci, vol.4, issue.10, pp.1431-1440, 2016.

C. X. Nie, Novel heparin-mimicking polymer brush grafted carbon nanotube/ PES composite membranes for safe and efficient blood purification, J. Membr. Sci, vol.475, pp.455-468, 2015.

H. H. Hanssen, Metallic wires with an adherent lubricious and blood-compatible polymeric coating and their use in the manufacture of novel slippery-whenwet guidewires: Possible applications related to controlled local drug delivery, J. Biomed. Mater. Res, vol.48, issue.6, pp.820-828, 1999.

C. C. Peerlings, Heparin release from slippery-when-wet guide wires for intravascular use, J. Biomed. Mater. Res, vol.63, issue.6, pp.692-698, 2002.

R. T. Pijls, Flexible coils with a drug-releasing hydrophilic coating: A new platform for controlled delivery of drugs to the eye?, Bio-Med. Mater. Eng, vol.14, issue.4, pp.383-393, 2004.

Y. A. Liu, Improved antifouling properties of polyethersulfone membrane by blending the amphiphilic surface modifier with crosslinked hydrophobic segments, J. Membr. Sci, vol.486, pp.195-206, 2015.

D. Pavlenko, New low-flux mixed matrix membranes that offer superior removal of protein-bound toxins from human plasma, Sci. Rep, vol.6, p.34429, 2016.

, Biological evaluation of medical devices, issue.1, 2006.

L. H. Greene, Stability, activity and flexibility in alpha-lactalbumin, Protein Eng, vol.12, issue.7, pp.581-587, 1999.

S. V. Kumar, N-vinylpyrrolidone and ethoxyethyl methacrylate copolymer: Synthesis, characterization and reactivity ratios, J. Macromol. Sci. Part a-Pure Appl. Chem, vol.44, pp.1161-1169, 2007.

H. M. Song, Hemocompatibility and ultrafiltration performance of surfacefunctionalized polyethersulfone membrane by blending comb-like amphiphilic block copolymer, J. Membr. Sci, vol.471, pp.319-327, 2014.

S. Eloot, Experimental and Numerical Modeling of Dialysis, 2004.

M. Meireles, P. Aimar, and V. Sanchez, Albumin denaturation during ultrafiltrationeffects of operating-conditions and consequences on membrane fouling, Biotechnol. Bioeng, vol.38, issue.5, pp.528-534, 1991.

S. H. Yun, Platelet activation: the mechanisms and potential biomarkers, Biomed. Res. Int, 2016.

E. L. Pryzdial, Blood coagulation dissected, Transfus. Apheres. Sci, vol.57, issue.4, pp.449-457, 2018.

E. Castoldi and J. Rosing, Thrombin generation tests, Thromb. Res, vol.127, pp.21-25, 2011.