M. Abayazid, M. Kemp, and S. Misra, 3d flexible needle steering in soft-tissue phantoms using fiber bragg grating sensors, Proc. IEEE International Conference on Robotics and Automation (ICRA), pp.5843-5849, 2013.

R. Adams and L. Bischof, Seeded region growing, IEEE Transactions, vol.16, issue.6, pp.641-647, 1994.

R. L. Bishop, There is more than one way to frame a curve, The American Mathematical Monthly, vol.82, issue.3, pp.246-251, 1975.

A. Bonvilain and M. Gangneron, Characterization of strain microgauges for the monitoring of the deformations of a medical needle during its insertion in human tissues, Microsystem Technologies, vol.22, issue.3, pp.551-556, 2016.
URL : https://hal.archives-ouvertes.fr/hal-01459830

A. Bonvilain, L. Zanardelli, and A. Carriquiry, Piezoresistif microsensors for an instrumented medical needle for its real time monitoring in a microlocalization tool, Microsystem Technologies, vol.24, issue.7, pp.3161-3167, 2018.
URL : https://hal.archives-ouvertes.fr/hal-01972321

C. De-boor, A Practical Guide to Splines, 1978.

P. N. Brett, T. Parker, A. J. Harrison, T. A. Thomas, and A. Carr, Simulation of resistance forces acting on surgical needles, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol.211, issue.4, pp.335-347, 1997.

R. H. Byrd, J. Nocedal, and R. A. Waltz, Knitro: An integrated package for nonlinear optimization, Large-scale nonlinear optimization, pp.35-59, 2006.

E. Cosserat and F. Cosserat, Théorie des corps déformables, 1909.

P. Craven and G. Wahba, Smoothing noisy data with spline functions, Numerische Mathematik, vol.31, issue.4, pp.377-403, 1978.

C. Fouard, A. Deram, Y. Keraval, and E. Promayon, CamiTK: a modular framework integrating visualization, image processing and biomechanical modeling, pp.323-354, 2012.
URL : https://hal.archives-ouvertes.fr/hal-00806781

H. Guggenheimer, Computing frames along a trajectory, Computer Aided Geometric Design, vol.6, issue.1, pp.77-78, 1989.

E. Hairer, G. Wanner, and C. Lubich, Geometric Numerical Integration. Structure-Preserving Algorithms for Ordinary Differential Equations, 2 edn, 2006.
URL : https://hal.archives-ouvertes.fr/hal-01403326

H. Haron, A. Rehman, D. Adi, S. Lim, T. Saba et al., Accurate and efficient fiber optical shape sensor for mri compatible minimally invasive instruments, vol.15, 2012.

K. Henken, D. V. Gerwen, J. Dankelman, and J. V. Dobbelsteen, Accuracy of needle position measurements using fiber bragg gratings, Minimally Invasive Therapy & Allied Technologies, vol.21, issue.6, pp.408-414, 2012.

K. R. Henken, J. Dankelman, J. J. Van-den-dobbelsteen, L. K. Cheng, and M. S. Van-der-heiden, Error analysis of fbg-based shape sensors for medical needle tracking, vol.19, pp.1523-1531, 2014.

G. Hocking, S. Hebard, and C. H. Mitchell, A review of the benefits and pitfalls of phantoms in ultrasoundguided regional anesthesia, Regional anesthesia and pain medicine, vol.36, issue.2, pp.162-170, 2011.

S. Jiang, P. Li, Y. Yu, J. Liu, and Z. Yang, Experimental study of needletissue interaction forces: Effect of needle geometries, insertion methods and tissue characteristics, Journal of Biomechanics, vol.47, issue.13, pp.3344-3353, 2014.

B. Kim, J. Ha, F. C. Park, and P. E. Dupont, Optimizing curvature sensor placement for fast, accurate shape sensing of continuum robots, 2014 IEEE International Conference on Robotics and Automation (ICRA), pp.5374-5379, 2014.

G. Kirchhoff, Uber das gleichgewicht und die bewegung eines unendlich dunnen elastischen stabes, J. Reine Angew. Math, vol.56, pp.285-313, 1859.

L. Digabel and S. , Algorithm 909: Nomad: Nonlinear optimization with the mads algorithm, ACM Trans. Math. Softw, vol.37, issue.4, p.15, 2011.

,

E. Lee, Choosing nodes in parametric curve interpolation, Computer-Aided Design, vol.21, issue.6, pp.363-370, 1989.

A. E. Love, A treatise on the mathematical theory of elasticity, 2 edn, 1906.

W. Magnus, On the exponential solution of differential equations for a linear operator, Communications on Pure and Applied Mathematics, vol.7, issue.4, pp.649-673, 1954.

A. W. Mahoney, T. L. Bruns, P. J. Swaney, and R. J. Webster, On the inseparable nature of sensor selection, sensor placement, and state estimation for continuum robots or where to put your sensors and how to use them, Robotics and Automation (ICRA), 2016 IEEE International Conference on, pp.4472-4478, 2016.

F. Monasa and G. Lewis, Large deflections of point loaded cantilevers with nonlinear behaviour, ZAMP Zeitschrift fr angewandte Mathematik und Physik, vol.34, issue.1, pp.124-130, 1983.

H. Moon, J. Jeong, S. Kang, K. Kim, Y. W. Song et al., Fiber-bragg-grating-based ultrathin shape sensors displaying single-channel sweeping for minimally invasive surgery, Optics and Lasers in Engineering, vol.59, pp.50-55, 2014.

P. Moreira and S. Misra, Biomechanics-based curvature estimation for ultrasound-guided flexible needle steering in biological tissues, Annals of Biomedical Engineering, vol.43, issue.8, pp.1716-1726, 2015.

K. W. Ng, J. Q. Goh, S. L. Foo, P. H. Ting, and T. K. Lee, Needle insertion forces studies for optimal surgical modeling, International Journal of Bioscience, Biochemistry and Bioinformatics, vol.3, issue.3, p.187, 2013.

Y. L. Park, S. Elayaperumal, B. Daniel, S. C. Ryu, M. Shin et al., Real-time estimation of 3-d needle shape and deflection for mri-guided interventions, vol.15, pp.906-915, 2010.

T. K. Podder, D. P. Clark, and J. Sherman, Effects of tip geometry of surgical needle an assessment of force and deflection. Third European medical and biological engineering conference, pp.1641-1644, 2005.

D. L. Ragozin, Error bounds for derivative estimates based on spline smoothing of exact or noisy data, Journal of Approximation Theory, vol.37, issue.4, pp.335-355, 1983.

,

C. K. Rao and A. P. Deshpande, Modelling of engineering materials, 2010.

E. Reissner, On one-dimensional large-displacement finite-strain beam theory, Studies in Applied Mathematics, vol.52, issue.2, pp.87-95, 1973.

J. Rice and M. Rosenblatt, Integrated mean squared error of a smoothing spline, Journal of Approximation Theory, vol.33, issue.4, pp.90066-90072, 1981.

A. L. Robert, G. Chagnon, I. Bricault, P. Cinquin, and A. Moreau-gaudry, A generic three-dimensional static force distribution basis for a medical needle inserted into soft tissue, Journal of the Mechanical Behavior of Biomedical Materials, vol.28, pp.156-170, 2013.
URL : https://hal.archives-ouvertes.fr/hal-00963794

R. Governi and M. P. , From unordered point cloud to weighted b-spline -a novel pca-based method, Applications of Mathematics and Computer Engineering, 2011.

R. Roesthuis, M. Kemp, J. Van-den-dobbelsteen, and S. Misra, Three-dimensional needle shape reconstruction using an array of fiber bragg grating sensors, vol.19, pp.1115-1126, 2014.

R. J. Roesthuis, S. Janssen, and S. Misra, On using an array of fiber bragg grating sensors for closed-loop control of flexible minimally invasive surgical instruments, 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems, pp.2545-2551, 2013.

R. Rouchy, A. Moreau-gaudry, E. Chipon, S. Aubry, L. Pazart et al., Evaluation of the clinical benefit of an electromagnetic navigation system for ct-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional ct guidance (ctnav ii): study protocol for a randomised controlled trial, Trials, vol.18, issue.1, p.306, 2017.

R. Seifabadi, E. E. Gomez, F. Aalamifar, G. Fichtinger, and I. Iordachita, Real-time tracking of a bevel-tip needle with varying insertion depth: Toward teleoperated mri-guided needle steering, 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems, pp.469-476, 2013.

J. Simo and D. Fox, On a stress resultant geometrically exact shell model. part i: Formulation and optimal parametrization, Computer Methods in Applied Mechanics and Engineering, vol.72, issue.3, pp.90002-90011, 1989.

S. F. Sultan, G. Shorten, and G. Iohom, Simulators for training in ultrasound guided procedures, Medical ultrasonography, vol.15, issue.2, pp.125-131, 2013.

M. D. Todd, C. J. Stull, and M. Dickerson, A local material basis solution approach to reconstructing the threedimensional displacement of rod-like structures from strain measurements, Journal of Applied Mechanics, vol.80, issue.4, 2013.

G. Wan, Z. Wei, L. Gardi, D. B. Downey, and A. Fenster, Brachytherapy needle deflection evaluation and correction, Medical Physics, vol.32, issue.4, pp.902-909, 2005.

W. Wang, B. Jüttler, D. Zheng, and Y. Liu, Computation of rotation minimizing frames, ACM Transactions on Graphics (TOG), vol.27, issue.1, 2008.

S. Whittaker, G. Lethbridge, C. Kim, Z. Keon-cohen, and I. Ng, An ultrasound needle insertion guide in a porcine phantom model, Anaesthesia, vol.68, issue.8, pp.826-829

G. A. Wood, Data smoothing and differentiation procedures in biomechanics. Exercise and sport sciences reviews, vol.10, pp.308-362, 1982.

R. Xu, A. Yurkewich, and R. V. Patel, Shape sensing for torsionally compliant concentric-tube robots, 2016.

,