Résumé

Aim Neutron-activated holmium-166 (166Ho) is an excellent radionuclide for internal radiation therapy (Eβmax = 1.84 MeV) with an appropriate half-life (26.8 h), which emits photons (81 keV, 6.2%) suitable to be detected by gamma cameras. Preparing and injecting radiopharmaceuticals containing beta/gamma emitting holmium-166 implies a risk of exceeding the upper limit for skin and hand radiation equivalent doses (500 mSv/an). This study was aimed to estimate the whole body and finger exposure for staff responsible for dose preparation, dose dispensing, and dose injection of holmium-166 therapy. Methods To measure the finger dose from external exposure, all staff members wore TLD dosimeters. Personal dose equivalents Hp(10) were measured using electronic personal dosimeters (EPD MK2, Thermo Fischer Scientific) placed on the left side of the chest. During our study, staff members administered more than 40 166Ho-based therapies for preclinical trial. Appropriate radiation safety procedures and shielding were applied at each stage. Results In this study, the whole body doses were 2.80 ± 1.56 nSv MBq−1 for one 166Ho-therapy preparation/formulation, and 2.68 ± 1.70 nSv MBq−1 for one intravenous injection. Maximum finger doses were 2.9 ± 0.2 μSv MBq−1 and 2.5 ± 0.3 μSv MBq−1 for preparation and injection, respectively (activities injected: 72 ± 3 MBq). Conclusion Extrapolated annual doses from 300 166Ho radionuclide therapies were lower than the annual limit doses for skin and the whole body, 500 mSv and 20 mSv, respectively, reported in the European Directive EURATOM 96/29 when applying appropriate radiation protection standards. However, these doses have to be added to other diagnostic or therapeutic protocols, performed in preclinical facilities.
Fichier non déposé

Dates et versions

hal-02139104 , version 1 (24-05-2019)

Identifiants

Citer

Jacqueline Taleb, Marc Janier, Pauline Bonazza, Patrick Roux, Imen Miladi, et al.. Radiation dose measurements for staff members involved in holmium-166 preclinical trial. Radiation Measurements, 2013, 58, pp.75-78. ⟨10.1016/j.radmeas.2013.08.007⟩. ⟨hal-02139104⟩
67 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More