Estimation of Average Absorption Cross Section of a Skin Phantom in a mm-Wave Reverberation Chamber - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2019

Estimation of Average Absorption Cross Section of a Skin Phantom in a mm-Wave Reverberation Chamber

Résumé

The average absorption cross section (AACS) of a human skin-equivalent phantom is calculated under diffuse exposure in a reverberation chamber (RC) in the mm-wave band. Two methods are proposed, in the first method the quality factor of the RC is evaluated in the spectral domain. The second method is based on the theory of room electromagnetics and fitting power delay profile to obtain reverberation time. Similar results were obtained for both methods. AACS values of 225±0.048 cm 2 and 225±0.017 cm 2 were derived for the first and second method, respectively. These results are in good agreement.
Fichier principal
Vignette du fichier
1570504627.pdf (223.37 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-02133575 , version 1 (18-05-2019)

Identifiants

  • HAL Id : hal-02133575 , version 1

Citer

Reza Aminzadeh, Jérôme Sol, Philippe Besnier, Maxim Zhadobov, Luc Martens, et al.. Estimation of Average Absorption Cross Section of a Skin Phantom in a mm-Wave Reverberation Chamber. EUCAP 2019, Apr 2019, Krakow, Poland. ⟨hal-02133575⟩