A new assay to evaluate microvesicle plasmin generation capacity: validation in disease with fibrinolysis imbalance - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Journal of Extracellular Vesicles Année : 2018

A new assay to evaluate microvesicle plasmin generation capacity: validation in disease with fibrinolysis imbalance

Tarik Bouriche
  • Fonction : Auteur
Coralie Judicone
  • Fonction : Auteur
Philippe Poncelet
  • Fonction : Auteur

Résumé

Among extracellular vesicles, leukocyte-derived microvesicles (LMVs) have emerged as complex vesicular structures. Primarily identified as procoagulant entities, they were more recently ascribed to plasmin generation capacity (MV-PGC). The objectives of this work were (1) to develop a new hybrid bio-assay combining the specific isolation of LMVs and measurement of their PGC, and compare its performance to the original method based on centrifugation, (2) to validate MV-PGC in septic shock, combining increased levels of LMVs and fibrinolytic imbalance. Using plasma sample spiked with LMVs featuring different levels of PGC, we demonstrated that CD15-beads specifically extracted LMVs. The MV dependency of the test was demonstrated using electron microscopy, high speed centrifugation, nanofiltration and detergent-mediated solubilization and the MV-PGC specificity using plasmin-specific inhibitors, or antibodies blocking elastase or uPA. Thanks to a reaction booster (epsilon-ACA), we showed that the assay was more sensitive and reproducible than the original method. Moreover, it exhibited a good repeatability, inter-operator and inter-experiment reproducibility. The new immunomagnetic bio-assay was further validated in patients with septic shock. As a result, we showed that MV-PGC values were significantly lower in septic shock patients who died compared to patients who survived, both at inclusion and 24 h later (1.4 [0.8-3.0] vs 3.1 [1.7-18] A(405) x 10(-3)/min, p = 0.02; 1.4 [1-1.6] vs 5.2 [2.2-16] A(405) x 10(-3)/min, p = 0.004). Interestingly, combining both MV-PGC and PAI-1 in a ratio significantly improved the predictive value of PAI-1. This strategy, a hybrid capture bioassay to specifically measure LMV-PGC using for the first time, opens new perspectives for measuring subcellular fibrinolytic potential in clinical settings with fibrinolytic imbalance.
Fichier principal
Vignette du fichier
Cointe-Journal of Extracellular Vesicles-2018_1.pdf (2.36 Mo) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-02060265 , version 1 (26-05-2020)

Identifiants

Citer

Sylvie Cointe, Karim Harti Souab, Tarik Bouriche, Loris Vallier, Amandine Bonifay, et al.. A new assay to evaluate microvesicle plasmin generation capacity: validation in disease with fibrinolysis imbalance. Journal of Extracellular Vesicles, 2018, 7 (1), pp.1494482. ⟨10.1080/20013078.2018.1494482⟩. ⟨hal-02060265⟩
34 Consultations
122 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More