Study of two vanadium based materials as working electrode for developing a selective mixed-potential ammonia sensor - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2018

Study of two vanadium based materials as working electrode for developing a selective mixed-potential ammonia sensor

Résumé

Mixed potential ammonia gas sensors were fabricated by using two sensing materials of Ni3V2O8 and Au-V2O5 as working electrodes, YSZ as electrolyte and platinum as reference electrode. The results have shown that the Ni3V2O8 sensors show cross-sensitivity toward NO gas. However, Au-V2O5 working electrodes displayed a high sensitivity to NH3 as well as very fast response and recovery times at high temperatures. Furthermore, the results indicate that the selectivity of Au-V2O5sensors increases by increasing temperature.
Fichier principal
Vignette du fichier
G Nematbakhsh Eurosensors 2018.pdf (586.4 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-01996756 , version 1 (29-01-2019)

Identifiants

Citer

Gita Nematbakhsh Abkenar, Jean-Paul Viricelle, Mathilde Rieu, Philippe Breuil. Study of two vanadium based materials as working electrode for developing a selective mixed-potential ammonia sensor. EUROSENSORS 2018, Materials Center Leoben Forschungs GmbH; University of Graz (Uni Graz); Graz University of Technology (TU Graz), Sep 2018, Graz, Austria. pp.770, ⟨10.3390/proceedings2130770⟩. ⟨hal-01996756⟩
43 Consultations
45 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More