Packaged integrated opto-fluidic solution for harmful fluid analysis - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2016

Packaged integrated opto-fluidic solution for harmful fluid analysis

Résumé

Advances in nuclear fuel reprocessing have led to a surging need for novel chemical analysis tools. In this paper, we present a packaged lab-on-chip approach with co-integration of optical and micro-fluidic functions on a glass substrate as a solution. A chip was built and packaged to obtain light/fluid interaction in order for the entire device to make spectral measurements using the photo spectroscopy absorption principle. The interaction between the analyte solution and light takes place at the boundary between a waveguide and a fluid micro-channel thanks to the evanescent part of the waveguide’s guided mode that propagates into the fluid. The waveguide was obtained via ion exchange on a glass wafer. The input and the output of the waveguides were pigtailed with standard single mode optical fibers. The micro-scale fluid channel was elaborated with a lithography procedure and hydrofluoric acid wet etching resulting in a 150±8 μm deep channel. The channel was designed with fluidic accesses, in order for the chip to be compatible with commercial fluidic interfaces/chip mounts. This allows for analyte fluid in external capillaries to be pumped into the device through micro-pipes, hence resulting in a fully packaged chip. In order to produce this co-integrated structure, two substrates were bonded. A study of direct glass wafer-to-wafer molecular bonding was carried-out to improve detector sturdiness and durability and put forward a bonding protocol with a bonding surface energy of γ>2.0 J.m-2. Detector viability was shown by obtaining optical mode measurements and detecting traces of 1.2 M neodymium (Nd) solute in 12±1 μL of 0.01 M and pH 2 nitric acid (HNO3) solvent by obtaining an absorption peak specific to neodymium at 795 nm.
Fichier principal
Vignette du fichier
975011-2.pdf (767.8 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-01961213 , version 1 (23-10-2019)

Identifiants

Citer

T. Allenet, D. Bucci, F. Geoffray, F. Canto, L. Couston, et al.. Packaged integrated opto-fluidic solution for harmful fluid analysis. SPIE OPTO, Feb 2016, San Francisco, United States. pp.975011, ⟨10.1117/12.2212646⟩. ⟨hal-01961213⟩
56 Consultations
69 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More