C. Cai, T. Rodet, S. Legoupil, and A. Mohammad-djafari, A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography, Medical Physics, vol.38, issue.05, pp.111916-111931, 2013.
DOI : 10.1118/1.3547718

Y. Long and J. A. Fessler, Multi-Material Decomposition Using Statistical Image Reconstruction for Spectral CT, IEEE Transactions on Medical Imaging, vol.33, issue.8, pp.1614-1626, 2014.
DOI : 10.1109/TMI.2014.2320284

T. Weidinger, T. M. Buzug, T. Flohr, S. Kappler, and 7. K. Stierstorfer, Polychromatic Iterative Statistical Material Image Reconstruction for Photon-Counting Computed Tomography, International Journal of Biomedical Imaging, vol.80, issue.2, pp.1-15, 2016.
DOI : 10.1109/42.232263

K. Mechlem, S. Ehn, T. Sellerer, E. Braig, D. Munzel et al., Joint Statistical Iterative Material Image Reconstruction for Spectral Computed Tomography Using a Semi-Empirical Forward Model, IEEE Transactions on Medical Imaging, vol.37, issue.1, pp.1-1, 2017.
DOI : 10.1109/TMI.2017.2726687

R. F. Barber, E. Y. Sidky, T. G. Schmidt, and X. Pan, An algorithm for constrained one-step inversion of spectral CT data, Physics in Medicine and Biology, vol.61, issue.10, p.3784, 2016.
DOI : 10.1088/0031-9155/61/10/3784

R. E. Alvarez and A. Macovski, Energy-selective reconstructions in X-ray computerised tomography, Physics in Medicine and Biology, vol.21, issue.5, pp.733-744, 1976.
DOI : 10.1088/0031-9155/21/5/002

D. Pan, E. Roessl, J. Schlomka, S. D. Caruthers, A. Senpan et al., Computed Tomography in Color: NanoK-Enhanced Spectral CT Molecular Imaging, Computed Tomography in Color: NanoK-90 Enhanced Spectral CT Molecular Imaging, pp.9829-9833, 2010.
DOI : 10.1002/1522-2594(200012)44:6<867::AID-MRM7>3.0.CO;2-P

C. Maass, M. Baer, and M. Kachelriess, Image-based dual energy CT using optimized precorrection functions: A practical new approach of material decomposition in image domain, Medical Physics, vol.229, issue.3, pp.3818-3829, 2009.
DOI : 10.1118/1.596709

T. Niu, X. Dong, M. Petrongolo, and L. Zhu, Iterative image-domain decomposition for dual-energy CT, Medical Physics, vol.53, issue.17, 2014.
DOI : 10.1088/0031-9155/53/17/021

J. P. Schlomka, E. Roessl, R. Dorscheid, S. Dill, G. Martens et al., Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography, Physics in Medicine and Biology, vol.53, issue.15, p.4031, 2008.
DOI : 10.1088/0031-9155/53/15/002

J. Lesaint, S. Rit, R. Clackdoyle, and L. Desbat, Calibration for Circular Cone-Beam CT Based on Consistency Conditions, IEEE Transactions on Radiation and Plasma Medical Sciences, vol.1, issue.6, pp.517-526, 2017.
DOI : 10.1109/TRPMS.2017.2734844

URL : https://hal.archives-ouvertes.fr/hal-01686646

A. So and T. Lee, Rapid kV Switching Dual-Energy 35 CT Imaging, Dual-Energy CT in Cardiovascular Imaging, pp.45-60, 2015.
DOI : 10.1007/978-3-319-21227-2_4

T. G. Flohr, C. H. Mccollough, H. Bruder, M. Petersilka, K. Gruber et al., First performance evaluation of a dual-source CT (DSCT) system, European Radiology, vol.216, issue.3, pp.256-268, 2006.
DOI : 10.1148/radiology.216.2.r00au19457

B. Chen, Z. Zhang, E. Y. Sidky, D. Xia, and X. Pan, Image reconstruction and scan configurations enabled 45 by optimization-based algorithms in multispectral CT, Physics in Medicine & Biology, vol.62, issue.22, p.8763, 2017.

X. Pan, E. Y. Sidky, and M. Vannier, Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?, Inverse Problems, vol.25, issue.12, p.123009, 2009.
DOI : 10.1088/0266-5611/25/12/123009

P. Sukovic and N. H. Clinthorne, Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography, IEEE Transactions on Medical, vol.55

N. Maass, S. Sawall, M. Knaup, M. Kachelriess, P. R. Mendonca et al., Empirical multiple energy calibration (EMEC) for materialselective CT A 60 Flexible Method for Multi-Material Decomposition of Dual-Energy CT Images, IEEE transactions on medical imaging, vol.22, issue.33, pp.4222-4229, 2011.

C. H. Mccollough, G. H. Chen, W. Kalender, S. Leng, E. Samei et al., Achieving Routine Submillisievert CT Scanning: Report from the Summit on Management of Radiation Dose in CT, Radiology, vol.264, issue.2, pp.567-580, 2012.
DOI : 10.1148/radiol.12112265

J. A. Fessler, Method for statistically reconstructing images from a plurality of transmission measurements 70 having energy diversity and image reconstructor apparatus utilizing the method International Classification G06T5/00, pp.61-67, 2003.

S. S. Keerthi and E. G. Gilbert, Convergence of a Generalized SMO Algorithm for SVM Classifier Design, Machine 80 Learning, pp.351-360, 2002.

R. F. Barber and E. Y. Sidky, MOCCA: Mirrored convex/concave optimization for nonconvex composite functions, 2015.

A. Chambolle and T. Pock, A First-Order Primal-Dual Algorithm for Convex Problems with??Applications to Imaging, Journal of Mathematical Imaging and Vision, vol.60, issue.5, pp.120-145, 2011.
DOI : 10.1007/978-3-540-74936-3_22

URL : https://hal.archives-ouvertes.fr/hal-00490826

P. C. Hansen and M. Saxild-hansen, AIR Tools ??? A MATLAB package of algebraic iterative reconstruction methods, Journal of Computational and Applied Mathematics, vol.236, issue.8, pp.2167-2178, 2012.
DOI : 10.1016/j.cam.2011.09.039

G. Poludniowski, G. Landry, F. Deblois, P. M. Evans, and F. Verhaegen, : a program to calculate photon spectra from tungsten anode x-ray tubes, Physics in Medicine and Biology, vol.54, issue.19, pp.433-438, 2009.
DOI : 10.1088/0031-9155/54/19/N01

J. Beutel, Handbook of Medical Imaging: Medical Image Processing and Analysis, 2000.

A. Wirgin, The inverse crime, " arXiv:math-ph, p.100, 401050.

E. Y. Sidky, R. F. Barber, T. Gilat-schmidt, and X. Pan, Three material decomposition for spectral computed tomography enabled by block-diagonal steppreconditioning, 0105.

D. Kim, S. Ramani, and J. A. Fessler, Combining Ordered Subsets and Momentum for Accelerated X-Ray CT Image Reconstruction, IEEE Transactions on Medical Imaging, vol.34, issue.1, pp.167-178, 2015.
DOI : 10.1109/TMI.2014.2350962

D. C. Hansen and T. S. Sørensen, Fast 4D cone-beam CT from 60???s acquisitions, Physics and Imaging in Radiation Oncology, vol.5, pp.69-75, 2018.
DOI : 10.1016/j.phro.2018.02.004