Reproducibility in Echocardiographic Assessment of Diastolic Function in a Population Based Study (The STANISLAS Cohort Study)

Olivier Huttin
  • Fonction : Auteur
  • PersonId : 770504
  • IdRef : 127860991

Résumé

INTRODUCTION: There is limited evidence regarding intra-observer and inter-observer variations in echocardiographic measurements of diastolic function. This study aimed to assess this reproducibly within a population-based cohort study. METHODS: Sixty subjects in sinus rhythm were randomly selected among 4th visit participants of the STANISLAS Cohort (Lorraine region, France). This 4th examination systematically included M-mode, 2-dimensional, DTI and pulsed-wave Doppler echocardiograms. Reproducibility of variables was studied by intra-class correlation coefficients (ICC) and Bland Altman plots. RESULTS: Our population was on average middle-aged (50 ± 14 y), overweight (BMI = 26 ± 6 kg/m2) and non-smoking (87%) with a quarter of the participants having self-declared hypertension or treated with anti-hypertensive medication(s). Intra-observer ICC were > 0.90 for all analyzed parameters except for left ventricular ejection fraction (LVEF) which was 0.89 (0.81-0.93). The mean relative intra-observer differences were small and limits of agreement of relative differences were narrow for all considered parameters (<5% and <15% respectively). Inter-observer ICC were > 0.90 for all analyzed parameters except for LVEF (ICC = 0.87) and both mitral and pulmonary A wave duration (0.83 and 0.73 respectively). The mean relative inter-observer differences were <5% for all parameters except for pulmonary A wave duration (mean difference = 6.5%). Limits of agreement of relative differences were narrow (<15%), except for mitral A wave duration and velocity (both <20%) as well as left ventricular mass and pulmonary A wave duration (both <30%). Intra-observer agreements with regard to the presence and severity of diastolic dysfunction were excellent (Kappa = 0.93 (0.83-1.00) and 0.88 (0.75-0.99), respectively). CONCLUSION: In this validation study within the STANISLAS cohort, diastolic function echocardiographic parameters were found to be highly reproducible. Diastolic dysfunction consequently appears as a highly effective clinical and research tool.
Fichier principal
Vignette du fichier
journal.pone.0122336.PDF (1.1 Mo) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-01758213 , version 1 (04-04-2018)

Identifiants

Citer

Zied Frikha, Nicolas Girerd, Olivier Huttin, Pierre-Yves Courand, Erwan Bozec, et al.. Reproducibility in Echocardiographic Assessment of Diastolic Function in a Population Based Study (The STANISLAS Cohort Study). PLoS ONE, 2015, 10 (4), ⟨10.1371/journal.pone.0122336⟩. ⟨hal-01758213⟩
72 Consultations
144 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More