Comparison of projection- and image-based methods for proton stopping power estimation using dual energy CT

Résumé

Background and Purpose: Several strategies for estimating stopping power ratio (SPR) from dual-energy CT (DECT) have been proposed to improve accuracy of proton dose calculations. DECT methods can mainly be categorized into projection-based methods, where material decomposition is performed prior to image reconstruction, and image-based methods, where decomposition takes place after image reconstruction. With the advent of photon-counting and dual-layer technology, projection-based methods could be considered for SPR estimation. In this simulation-based study we compared the SPR accuracy of one projection-and three image-based DECT methods. Materials and Methods: X-ray CT projections of the female ICRP phantom were simulated using two different X-ray spectra with a realistic detector response and noise levels. ICRP slices at four different locations were selected. Reference SPR-maps were computed at 200 MeV. The SPR comparison was based on percentage deviation inside ROIs and relative range errors calculated with Radon transform of difference maps. Results: SPR root-mean-square errors (RMSE) over the selected ROIs were 0.54% for the projection-based method and 0.68%, 0.61% and 0.70% for the three image-based methods. The RMSE for the relative range errors were slightly smaller for the projection-based approach, but close to zero for all decomposition domains as positive and negative errors averaged out over the slice. Conclusions: SPR estimations with the projection-based method produced slightly better results (though not statistically significant) than the three image-based methods used in this simulation-based study, therefore, with the advent of technological developments, projection-based methods could be considered for SPR estimation if projection data is available.
Fichier principal
Vignette du fichier
1-s2.0-S240563161730012X-main.pdf (1003.37 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-01743242 , version 1 (26-03-2018)

Identifiants

Citer

Gloria Vilches-Freixas, Vicki Trier Taasti, Ludvig Paul Muren, Jørgen Breede Baltzer Petersen, Jean Michel Létang, et al.. Comparison of projection- and image-based methods for proton stopping power estimation using dual energy CT. Physics and Imaging in Radiation Oncology, 2017, 3, pp.28 - 36. ⟨10.1016/j.phro.2017.08.001⟩. ⟨hal-01743242⟩
100 Consultations
172 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More