Analytical dose modeling for preclinical proton irradiation of millimetric targets

Résumé

Purpose: Due to the considerable development of proton radiotherapy, several proton platforms have emerged to irradiate small animals in order to study the biological e ectiveness of proton ra- diation. A dedicated analytical treatment planning tool was developed in this study to accurately calculate the delivered dose given the speci c constraints imposed by the small dimensions of the irradiated areas. Methods: The treatment planning system (TPS) developed in this study is based on an analytical formulation of the Bragg peak and uses experimental range values of protons. The method was val- idated after comparison with experimental data from the literature and then compared to Monte Carlo simulations conducted using Geant4. Three examples of treatment planning, performed with phantoms made of water targets and bone-slab insert, were generated with the analytical formulation and Geant4. Each treatment planning was evaluated using dose-volume histograms and gamma index maps. Results: We demonstrate the value of the analytical function for mouse irradiation, which requires a targeting accuracy of 0.1 mm. Using the appropriate database, the analytical modelling limits the errors caused by misestimating the stopping power. For example, 99% of a 1-mm tumor irra- diated with a 24 MeV beam receives the prescribed dose. The analytical dose deviations from the prescribed dose remain within the dose tolerances stated by report 62 of the International Commis- sion on Radiation Units and Measurements for all tested con gurations. In addition, the gamma index maps show that the highly constrained targeting accuracy of 0.1 mm for mouse irradiation leads to a signi cant disagreement between Geant4 and the reference. This simulated treatment planning is nevertheless compatible with a targeting accuracy exceeding 0.2 mm, corresponding to rat and rabbit irradiations. Conclusion: Good dose accuracy for millimetric tumors is achieved with the analytical calcu- lation used in this work. These volume sizes are typical in mouse models for radiation studies. Our results demonstrate that the choice of analytical rather than simulated treatment planning depends on the animal model under consideration.
Fichier non déposé

Dates et versions

hal-01700779 , version 1 (05-02-2018)

Identifiants

Citer

Marie Vanstalle, Julie Constanzo, Yusuf Karakaya, Christian Finck, Marc Rousseau, et al.. Analytical dose modeling for preclinical proton irradiation of millimetric targets. Medical Physics, 2018, 45 (1), pp.470 - 478. ⟨10.1002/mp.12696⟩. ⟨hal-01700779⟩
220 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More