Skip to Main content Skip to Navigation
Journal articles

Measurement of implant deployment and related forces in kyphoplasty by percutaneous approach

Abstract : BACKGROUND: The treatment of osteoporotic vertebral compression fractures using a transpedicular approach and cement injection has grown significantly over the last two decades. METHODS: The aim was to study the deployment of an implant dedicated to the vertebral augmentation by percutaneous approach (kyphoplasty). Its kinematics and the related forces have been investigated. A theoretical model of deployment has been proposed and the ancillary was instrumented with strain gauges and Hall effect sensors to measure kinematics and force in the deployment actuator (tensile rod). The methodology was first evaluated ex-vivo in a test-bench with boundary conditions monitored by a tensile machine. Then, a cadaver study was carried out in three lumbar and thoracic vertebral segments of normal and osteoporotic spines. FINDINGS: The relationships between ancillary internal forces, deployment, and cranio-caudal pushing force have been obtained. The test-bench experiment showed quasi-proportional relationship between force distribution and kinematics during the deployment. Ex-vivo cranio-caudal pushing forces were measured. Cadaver studies showed cranio-caudal pushing forces comprised between 100N and 200N. These forces were dependent upon the implant location in the vertebral body and bone stock. INTERPRETATION: The methodology was related to the analysis of load distribution and kinematics of a deployable implant for vertebral augmentation. The ancillary instrumentation contributed to the objective quantification of the surgical technique. The cadaver study in normal and osteoporotic spines exhibited the role of bone properties and implant location in implant deployment. This pilot study showed a methodology to improve the kyphoplasty surgery and patient comfort in clinical routine.
Complete list of metadatas

Cited literature [3 references]  Display  Hide  Download

https://hal.archives-ouvertes.fr/hal-01585301
Contributor : Open Archive Toulouse Archive Ouverte (oatao) <>
Submitted on : Monday, September 11, 2017 - 2:44:44 PM
Last modification on : Thursday, June 18, 2020 - 11:14:31 AM

File

Bolzinger_18157.pdf
Files produced by the author(s)

Identifiers

Collections

Citation

F. Bolzinger, J.F. Oglaza, A. Krüger, Pascal Swider. Measurement of implant deployment and related forces in kyphoplasty by percutaneous approach. Clinical Biomechanics, Elsevier, 2014, vol. 29 (n° 4), pp. 463-467. ⟨10.1016/j.clinbiomech.2014.01.001⟩. ⟨hal-01585301⟩

Share

Metrics

Record views

126

Files downloads

209