Magnetic resonance temperature imaging, International Journal of Hyperthermia, vol.13, issue.6, pp.515-531, 2005. ,
DOI : 10.1002/mrm.10608
URL : https://hal.archives-ouvertes.fr/hal-00308326
MR thermometry, Journal of Magnetic Resonance Imaging, vol.55, issue.2, pp.376-390, 2008. ,
DOI : 10.1148/radiology.171.3.2717764
Early Results, American Journal of Roentgenology, vol.183, issue.6, pp.1713-1719, 2004. ,
DOI : 10.2214/ajr.183.6.01831713
Minimally Invasive Treatment of Malignant Hepatic Tumors: At the Threshold of a Major Breakthrough, RadioGraphics, vol.20, issue.1, pp.9-27, 2000. ,
DOI : 10.1148/radiographics.20.1.g00ja019
Magnetic Resonance Temperature Imaging for Focused Ultrasound Surgery, Topics in Magnetic Resonance Imaging, vol.17, issue.3, pp.153-63, 2006. ,
DOI : 10.1097/RMR.0b013e3180377bc3
Thermal dose determination in cancer therapy, International Journal of Radiation Oncology*Biology*Physics, vol.10, issue.6, pp.787-800, 1964. ,
DOI : 10.1016/0360-3016(84)90379-1
Three-dimensional spatial and temporal temperature control with MR thermometry-guided focused ultrasound (MRgHIFU), Magnetic Resonance in Medicine, vol.57, issue.3, pp.603-614, 2009. ,
DOI : 10.1016/0360-3016(84)90379-1
Image-guided, noninvasive, spatiotemporal control of gene expression, Proceedings of the National Academy of Sciences, vol.34, issue.6, pp.1175-1180, 2009. ,
DOI : 10.1002/mrm.1910340606
Signal-to-noise in phase angle reconstruction: Dynamic range extension using phase reference offsets, Magnetic Resonance in Medicine, vol.6, issue.3, pp.420-437, 1990. ,
DOI : 10.1148/radiology.156.3.4023236
A fast gradient-recalled MRI technique with increased sensitivity to dynamic susceptibility effects, Magnetic Resonance in Medicine, vol.88, issue.1, pp.184-189, 1992. ,
DOI : 10.1002/mrm.1910260118
SENSE: Sensitivity encoding for fast MRI, Magnetic Resonance in Medicine, vol.30, issue.5, pp.952-962, 1999. ,
DOI : 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S
URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.139.3032
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays, Magnetic Resonance in Medicine, vol.18, issue.4, pp.591-603, 1997. ,
DOI : 10.1002/mrm.1910350419
Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI, Magnetic Resonance in Medicine, vol.93, issue.5, pp.813-828, 1999. ,
DOI : 10.1148/radiology.195.2.7724769
k-t BLAST andk-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations, Magnetic Resonance in Medicine, vol.46, issue.5, pp.1031-1042, 2003. ,
DOI : 10.1002/mrm.10611
URL : http://onlinelibrary.wiley.com/doi/10.1002/mrm.10611/pdf
In vivo demonstration of noninvasive thermal surgery of the liver and kidney using an ultrasonic phased array, Ultrasound in Medicine & Biology, vol.25, issue.7, pp.1087-1098, 1999. ,
DOI : 10.1016/S0301-5629(99)00053-8
Magnetic resonance-guided focused ultrasound surgery (MRgFUS). Four ablation treatments of a single canine hepatocellular adenoma, HPB, vol.8, issue.4, pp.292-298, 2006. ,
DOI : 10.1080/13651820500465212
Real-time 3D target tracking in MRI guided focused ultrasound ablations in moving tissues, Magnetic Resonance in Medicine, vol.37, issue.6, pp.1704-1712, 2010. ,
DOI : 10.1002/mrm.1910370121
URL : https://hal.archives-ouvertes.fr/hal-01064527
Real-time MR-thermometry and dosimetry for interventional guidance on abdominal organs, Magnetic Resonance in Medicine, vol.13, issue.4, pp.1080-1087, 2010. ,
DOI : 10.1016/0360-3016(84)90379-1
URL : https://hal.archives-ouvertes.fr/hal-01504325
Focal spacing and near-field heating during pulsed high temperature ultrasound therapy, Ultrasound in Medicine & Biology, vol.19, issue.9, pp.777-787, 1993. ,
DOI : 10.1016/0301-5629(93)90094-5
Quantification of near-field heating during volumetric MR-HIFU ablation, Medical Physics, vol.22, issue.4, pp.272-282, 2011. ,
DOI : 10.1016/0301-5629(96)00026-9
Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidney, NMR in Biomedicine, vol.52, issue.2, pp.145-153, 2011. ,
DOI : 10.1002/mrm.20280
URL : https://hal.archives-ouvertes.fr/hal-01064550
Model-Based Ultrasound Temperature Visualization During and Following Hifu Exposure, Ultrasound in Medicine & Biology, vol.36, issue.2, pp.234-249, 2010. ,
DOI : 10.1016/j.ultrasmedbio.2009.10.001
Model predictive filtering for improved temporal resolution in MRI temperature imaging, Magnetic Resonance in Medicine, vol.57, issue.suppl 2, pp.1269-1279, 2010. ,
DOI : 10.1016/0360-3016(85)90343-8
Robust Adaptive Extended Kalman Filtering for Real Time MR-Thermometry Guided HIFU Interventions, IEEE Transactions on Medical Imaging, vol.31, issue.3, pp.533-542, 2012. ,
DOI : 10.1109/TMI.2011.2171772
URL : https://hal.archives-ouvertes.fr/hal-00994212
A New Approach to Linear Filtering and Prediction Problems, Journal of Basic Engineering, vol.82, issue.1, pp.35-45, 1960. ,
DOI : 10.1115/1.3662552
Temporally constrained reconstruction applied to MRI temperature data, Magnetic Resonance in Medicine, vol.57, issue.2, pp.406-419, 2009. ,
DOI : 10.1016/0360-3016(84)90379-1
URL : http://onlinelibrary.wiley.com/doi/10.1002/mrm.22012/pdf
Reconstruction of fully three-dimensional high spatial and temporal resolution MR temperature maps for retrospective applications, Magnetic Resonance in Medicine, vol.10, issue.Suppl 1, pp.724-730, 2012. ,
DOI : 10.1016/0360-3016(84)90379-1
Toward real-time availability of 3D temperature maps created with temporally constrained reconstruction, International Society for Magnetic Resonance in Medicine, 20th annual Meeting, 2012. ,
DOI : 10.1002/mrm.20090
Analysis of tissue and arterial blood temperatures in the resting human forearm, Journal of applied physiology, vol.1, issue.2, pp.93-122, 1948. ,
MRgHIFU: Feedback temperature control with automatic deduction of BHT tissue parameters, 8th International Symposium on Therapeutic Ultrasound, pp.231-235, 2009. ,
DOI : 10.1063/1.3131419
Automatic control of hyperthermic therapy based on real-time Fourier analysis of MR temperature maps, Magnetic Resonance in Medicine, vol.45, issue.6, pp.1065-1072, 2002. ,
DOI : 10.1002/1522-2594(200101)45:1<128::AID-MRM1017>3.0.CO;2-M
Focus splitting associated with propagation of focused ultrasound through the rib cage, Acoustical Physics, vol.56, issue.5, pp.665-674, 2010. ,
DOI : 10.1134/S106377101005012X
Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound, Magnetic Resonance in Medicine, vol.12, issue.2, pp.319-330, 2007. ,
DOI : 10.1109/ICIP.2000.901003
URL : https://hal.archives-ouvertes.fr/hal-00308327
The proton resonance frequency shift method compared with molecular diffusion for quantitative measurement of two dimensional time dependent temperature distribution in phantom, Journal of Magnetic Resonance Imaging, vol.103, pp.234-241, 1994. ,
MR-Guided Thermotherapy of Abdominal Organs Using a Robust PCA-Based Motion Descriptor, IEEE Transactions on Medical Imaging, vol.30, issue.11, pp.1987-1995, 2011. ,
DOI : 10.1109/TMI.2011.2161095
URL : https://hal.archives-ouvertes.fr/hal-01063781