Image correlation for shape, motion and deformation measurements -basic concepts, theory and applications, 2009. ,
Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review, Measurement Science and Technology, vol.20, issue.6, p.62001, 2009. ,
DOI : 10.1088/0957-0233/20/6/062001
2012) Full-field measurements and identification in solid mechanics ,
3-D computer vision in experimental mechanics, Optics and Lasers in Engineering, vol.47, issue.3-4, pp.282-291, 2009. ,
DOI : 10.1016/j.optlaseng.2007.11.009
The effect of out-of-plane motion on 2D and 3D digital image correlation measurements, Optics and Lasers in Engineering, vol.46, issue.10, pp.746-757, 2008. ,
DOI : 10.1016/j.optlaseng.2008.05.005
3D Strain Field Measurement by Correlation of Volume Images Using Scattered Light: Recording of Images and Choice of Marks, Strain, vol.17, issue.3, pp.207-218, 2007. ,
DOI : 10.1117/12.7976778
URL : https://hal.archives-ouvertes.fr/hal-00239902
3D micro-scale deformations of wood in bending: Synchrotron radiation ??CT data analyzed with digital volume correlation, Journal of Structural Biology, vol.164, issue.3, pp.255-262, 2008. ,
DOI : 10.1016/j.jsb.2008.08.004
3D mechanical analysis of low-density wood-based fiberboards by X-ray microcomputed tomography and Digital Volume Correlation, Journal of Materials Science, vol.43, issue.3, pp.3198-3212, 2013. ,
DOI : 10.1111/j.1475-1305.2007.00340.x
Volumetric Digital Image Correlation Applied to X-ray Microtomography Images from Triaxial Compression Tests on Argillaceous Rock, Strain, vol.23, issue.3, pp.193-205, 2007. ,
DOI : 10.1520/GTJ11051J
URL : https://hal.archives-ouvertes.fr/hal-00541503
Three-dimensional Traction Force Microscopy for Studying Cellular Interactions with Biomaterials, Procedia IUTAM, vol.4, pp.144-150, 2012. ,
DOI : 10.1016/j.piutam.2012.05.016
URL : http://doi.org/10.1016/j.piutam.2012.05.016
Imaging three-dimensional myocardial mechanics using navigator-gated volumetric spiral cine DENSE MRI, Magnetic Resonance in Medicine, vol.13, issue.Suppl I, pp.1089-1097, 2010. ,
DOI : 10.1161/01.CIR.101.9.981
URL : http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2946451
Full-field speckle pattern image correlation with B-Spline deformation function, Experimental Mechanics, vol.39, issue.11, pp.344-352, 2002. ,
DOI : 10.1007/BF02410992
???Finite-Element??? Displacement Fields Analysis from Digital Images: Application to Portevin???Le Ch??telier Bands, Experimental Mechanics, vol.404, issue.3, pp.789-803, 2006. ,
DOI : 10.1080/14786440808520347
URL : https://hal.archives-ouvertes.fr/hal-00124513/document
Measuring stress intensity factors with a camera: Integrated digital image correlation (I-DIC), Comptes Rendus M??canique, vol.334, issue.1, pp.8-12, 2006. ,
DOI : 10.1016/j.crme.2005.11.002
URL : https://hal.archives-ouvertes.fr/hal-00322201
Use of rigid-body motion for the investigation and estimation of the measurement errors related to digital image correlation technique, Optics and Lasers in Engineering, vol.46, issue.2, pp.185-196, 2008. ,
DOI : 10.1016/j.optlaseng.2007.05.008
Applications of digital-image-correlation techniques to experimental mechanics, Experimental Mechanics, vol.1, issue.3, pp.232-244, 1985. ,
DOI : 10.1117/12.7972925
Effects Of Subpixel Image Restoration On Digital Correlation Error Estimates, Optical Engineering, vol.27, issue.10, pp.870-877, 1988. ,
DOI : 10.1117/12.7976778
Measurement of deformations on concrete subjected to compression using image correlation, Experimental Mechanics, vol.2, issue.11, pp.307-313, 1997. ,
DOI : 10.1117/12.7976778
Stress intensity factor measurements from digital image correlation: post-processing and integrated approaches, International Journal of Fracture, vol.40, issue.1, pp.141-157, 2006. ,
DOI : 10.1117/12.7976778
URL : https://hal.archives-ouvertes.fr/hal-00013818
Quantitative Error Assessment in Pattern Matching: Effects of Intensity Pattern Noise, Interpolation, Strain and Image Contrast on Motion Measurements, Strain, vol.47, issue.2, pp.160-178, 2009. ,
DOI : 10.1007/s11340-006-9005-9
Assessment of Digital Image Correlation Measurement Errors: Methodology and Results, Experimental Mechanics, vol.43, issue.4, pp.353-370, 2009. ,
DOI : 10.1117/12.7972925
URL : https://hal.archives-ouvertes.fr/hal-00881043
Digital Image Correlation with Enhanced Accuracy and Efficiency: A Comparison of Two Subpixel Registration Algorithms, Experimental Mechanics, vol.50, issue.1, pp.1395-1409, 2016. ,
DOI : 10.1111/str.12066
Theoretical Analysis on the Measurement Errors of Local 2D DIC: Part I Temporal and Spatial Uncertainty Quantification of Displacement Measurements, Strain, vol.40, issue.2, pp.110-128, 2016. ,
DOI : 10.1117/1.1387992
Microextensometry by image correlation applied to micromechanical studies using the scanning electron microscopy, Proc. International conference on advanced technology in experimental mechanics, pp.81-86, 1999. ,
URL : https://hal.archives-ouvertes.fr/hal-00116552
Analysis of strain localization during tensile tests by digital image correlation, Experimental Mechanics, vol.37, issue.1, pp.29-39, 2000. ,
DOI : 10.1007/BF02323101
Systematic errors in digital image correlation caused by intensity interpolation, Optical Engineering, vol.39, issue.11, pp.2915-2921, 2000. ,
DOI : 10.1117/1.1314593
Subpixel displacement and deformation gradient measurement using digital image/speckle correlation (DISC), Optical Engineering, vol.40, issue.8, p.1613, 2001. ,
DOI : 10.1117/1.1387992
Full-field measurements of heterogeneous deformation patterns on polymeric foams using digital image correlation, International Journal of Solids and Structures, vol.39, issue.13-14, pp.3777-3796, 2002. ,
DOI : 10.1016/S0020-7683(02)00176-2
Systematic errors in digital image correlation due to undermatched subset shape functions, Experimental Mechanics, vol.41, issue.1, pp.303-310, 2002. ,
DOI : 10.1007/BF02410987
Performance of sub-pixel registration algorithms in digital image correlation, Meas Sci Technol, vol.17, pp.1615-1621, 2006. ,
Quality assessment of speckle patterns for digital image correlation, Optics and Lasers in Engineering, vol.44, issue.11, pp.1132-1145, 2006. ,
DOI : 10.1016/j.optlaseng.2005.10.004
Parameter choice for optimized digital image correlation, Optics and Lasers in Engineering, vol.47, issue.6, pp.728-737, 2009. ,
DOI : 10.1016/j.optlaseng.2008.10.015
URL : https://hal.archives-ouvertes.fr/hal-00334368
Evaluation of the quality of a speckle pattern in the digital image correlation method by mean subset fluctuation, Optics & Laser Technology, vol.43, issue.1, pp.9-13, 2011. ,
DOI : 10.1016/j.optlastec.2010.04.010
Mean intensity gradient: An effective global parameter for quality assessment of the speckle patterns used in digital image correlation, Optics and Lasers in Engineering, vol.48, issue.4, pp.469-477, 2010. ,
DOI : 10.1016/j.optlaseng.2009.08.010
Cross-Correlation and Differential Technique Combination to Determine Displacement Fields, Strain, vol.41, pp.87-98, 2011. ,
DOI : 10.1007/BF02323101
Short remarks about synthetic image generation in the context of the assessment of sub-pixel accuracy of digital image correlation, Proc. International Conference on Experimental Mechanics (ICEM'15), 2012. ,
Experimental and Numerical Methods for Exact Subpixel Shifting, Experimental Mechanics, vol.41, issue.32, pp.443-452, 2011. ,
DOI : 10.1364/AO.41.006815
On the use of the digital image correlation method for heterogeneous deformation measurement of porous solids, Optics and Lasers in Engineering, vol.49, issue.2, pp.200-209, 2011. ,
DOI : 10.1016/j.optlaseng.2010.09.015
Assessment of Digital Image Correlation Measurement Accuracy in the Ultimate Error Regime: Main Results of a Collaborative Benchmark, Strain, vol.45, issue.6, pp.483-496, 2013. ,
DOI : 10.1111/j.1475-1305.2008.00592.x
URL : https://hal.archives-ouvertes.fr/hal-01069741