Respiratory signal extraction for 4D CT imaging of the thorax from cone-beam CT projections - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2005

Respiratory signal extraction for 4D CT imaging of the thorax from cone-beam CT projections

Résumé

The purpose of this study was the four-dimensional (4D) imaging of a free-breathing thorax with the Elekta Synergy cone-beam (CB) for 4D radiotherapy. The first step consisted in facing the slowness of the acquisition by retrospectively sorting CB projections with a respiratory signal. We propose to extract the respiratory signal directly from thorax CBCT projections instead of using an external device (spirometer, infrared camera). We firstly simulated a set of CBCT images with a 4D CT model for the development and the validation of the method. From the simulation output, we secondly extracted, selected and integrated motion information to obtain the respiratory signal.

Dates et versions

hal-01505715 , version 1 (11-04-2017)

Identifiants

Citer

Simon Rit, David Sarrut, C Ginestet. Respiratory signal extraction for 4D CT imaging of the thorax from cone-beam CT projections. American Society for Therapeutic Radiology and Oncology (ASTRO), Oct 2005, Denver, United States. pp.S534, ⟨10.1016/j.ijrobp.2005.07.901⟩. ⟨hal-01505715⟩