M. Deimling and O. Heid, Magnetization prepared true FISP imaging, Proceedings of the 2nd Annual Meeting of ISMRM, 1994.

P. Mansfield, Multi-planar image formation using NMR spin echoes, Journal of Physics C: Solid State Physics, vol.10, issue.3, pp.5-58, 1977.
DOI : 10.1088/0022-3719/10/3/004

K. Pruessmann, M. Weiger, M. Scheidegger, and P. Boesiger, SENSE: Sensitivity encoding for fast MRI, Magnetic Resonance in Medicine, vol.30, issue.5, pp.952-962, 1999.
DOI : 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.139.3032

D. Sodickson and W. Manning, Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays, Magnetic Resonance in Medicine, vol.18, issue.4, pp.591-603, 1997.
DOI : 10.1002/mrm.1910380414

P. Jezzard and R. Balaban, Correction for geometric distortion in echo planar images from B0 field variations, Magnetic Resonance in Medicine, vol.29, issue.1, pp.65-73, 1995.
DOI : 10.1002/mrm.1910340111

P. Reber, E. Wong, R. Buxton, and L. Franck, Correction of off resonance-related distortion in echo-planar imaging using EPI-based field maps, Magnetic Resonance in Medicine, vol.28, issue.2, pp.328-330, 1998.
DOI : 10.1002/mrm.1910390223

H. Zeng and R. Constable, Image distortion correction in EPI: Comparison of field mapping with point spread function mapping, Magnetic Resonance in Medicine, vol.15, issue.1, pp.137-146, 2002.
DOI : 10.1002/mrm.10200

Q. Xiang and F. Ye, Correction for geometric distortion and N/2 ghosting in EPI by phase labeling for additional coordinate encoding (PLACE), Magnetic Resonance in Medicine, vol.53, issue.4
DOI : 10.1002/mrm.21187

A. Priest, D. Phil, D. Vita, E. Thomas, D. Ordidge et al., EPI distortion correction from a simultaneously acquired distortion map using TRAIL, Journal of Magnetic Resonance Imaging, vol.54, issue.4, pp.597-603, 2006.
DOI : 10.1002/jmri.20508

J. Kennedy, G. Ter-haar, and D. Cranston, High intensity focused ultrasound: surgery of the future?, The British Journal of Radiology, vol.76, issue.909, pp.590-599, 2003.
DOI : 10.1259/bjr/17150274

S. Levy, Biophysical basis and cardiac lesions caused by different techniques of cardiac arrhythmia ablation, Arch Mal Coeur Vaiss, vol.88, pp.1465-1469, 1995.

J. Hindman, Proton Resonance Shift of Water in the Gas and Liquid States, The Journal of Chemical Physics, vol.7, issue.12, pp.4582-4592, 1966.
DOI : 10.1063/1.1700780

R. Peters, R. Hinks, and R. Henkelman, Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry, Magnetic Resonance in Medicine, vol.15, issue.3, pp.454-459, 1998.
DOI : 10.1002/mrm.1910400316

T. Conturo and G. Smith, Signal-to-noise in phase angle reconstruction: Dynamic range extension using phase reference offsets, Magnetic Resonance in Medicine, vol.6, issue.3, pp.420-437, 1990.
DOI : 10.1002/mrm.1910150308

B. Denis-de-senneville, C. Mougenot, and C. Moonen, Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound, Magnetic Resonance in Medicine, vol.12, issue.2, pp.319-330, 2007.
DOI : 10.1002/mrm.21124

URL : https://hal.archives-ouvertes.fr/hal-00308327

C. Meyer, J. Pauly, A. Macovski, and D. Nishimura, Simultaneous spatial and spectral selective excitation, Magnetic Resonance in Medicine, vol.74, issue.2, pp.539-542, 1983.
DOI : 10.1002/mrm.1910150211

I. Pyrali, D. Schmidt, and R. Cytron, Techniques for enhancing real-time CORBA quality of service, Proceedings of IEEE Real-Time Systems Symposium (RTSS), pp.1070-1085, 2003.
DOI : 10.1109/JPROC.2003.814616

B. Denis-de-senneville, C. Mougenot, B. Quesson, I. Dragonu, N. Grenier et al., MR thermometry for monitoring tumor ablation, European Radiology, vol.6, issue.6, pp.2401-2410, 2007.
DOI : 10.1007/s00330-007-0646-6

URL : https://hal.archives-ouvertes.fr/hal-01503897

J. Dias and J. Leitao, InSAR phase unwrapping: a Bayesian approach, IGARSS 2001. Scanning the Present and Resolving the Future. Proceedings. IEEE 2001 International Geoscience and Remote Sensing Symposium (Cat. No.01CH37217), pp.396-400, 2001.
DOI : 10.1109/IGARSS.2001.976170

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.77.3405